Congratulations on your purchase of coating thickness gauge Paint PRO CONDTROL. Safety 

instructions provided in this user manual should be carefully read before you use the product for 

the first time.

SAFETY REGULATIONS

Attention!

 This user manual is an essential part of this product. The user manual should be read 

carefully before you use the product for the first time. If the product is given to someone for 

temporary use, be sure to enclose user manual to it.
- Do not misuse the product 

- Store the product beyond reach of children and unauthorized people.  

- It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified 

personnel and use original spare parts only.

- Do not use the product in explosive environment, close to flammable materials.

- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid 

contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with 

clean water during 10 minutes and consult the doctor.

FUNCTIONS/APPLICATIONS

Coating thickness gauge Paint PRO CONDTROL is designed for fast, precise and non-destructive  

measurement of coating thickness of both ferrous metals (method of electromagnetic induction) and 

non-ferrous metals (eddy current method).

This device can be used in production, in workshops, laboratories and quality control departments.

Distinctive features:

- Suitable for ferrous and non-ferrous metals

- Automatic or manual selection of the method of measurement 

- Single and continuous measurements

- Single and group measurements

- Determination of max. / min. / mean value, square deviation

- Sound indication for measurements out of the range

- Memory for 320 readings (80 per 1 group)

- USB interface for connection to PC, the program for data analysis

- LCD with backlight, function menu 

EXTERNAL APPEARANCE

1  USB connector

2  Display

3  Switch on/off button

4  Enter/exit menu

5  Up

6  Down/switch on/off the backlight

7  Confirm button

8  Return to previous section

9  Sensor

10 Battery cover

User manual

COATING THICKNESS GAUGE

EN

Paint PRO

Display

1 Indication of measurement mode

2 Battery charge level indication

3 Number of measurement in memory

4 Current measurement result

5 Measuring unit

6 Type of surface indication  

(Fe-magnetic, N – non-magnetic)

7 Maximal value

8 Minimal value

9 Mean value

Menu

The menu of the device consists of the following settings:

1. Recall – Memory

2. Delete – Memory cleaning

3. Calibration 

4. Alarm – sound indication for measurements out of the range

5. Count - Statistics

6. Mode 

    6.1. Sensor – select the sensor

    6.2. Group – groups of measurements

    6.3. Measure – modes of measurement

    6.4. Unit – measuring unit

    6.5. Language 

7. Recovery – reset to factory settings

TECHNICAL SPECIFICATIONS

Modes of measurement

Single/Continuous 

Measuring unit

µm (0…999 µm); / mm (≥1000 µm)

Measuring range

0…1500 µm

Smallest unit displayed

1 µm (0…999 µm); / 0.01 mm (≥1000 µm)

Accuracy

±3% + 2 µm

Substrate thickness

>0.5 mm

Curvature radius of convex surface

>1.5 mm

Curvature radius of concave surface

>25 mm

Measurement area diameter

>6 mm

Display backlight

V

Automatic shutdown 

3 min.

Power supply

2 x 1.5V AAA 

Operating temperature 

0…45

0

C

Operating humidity

0…90%RH (no condensation and no strong magnetic field)

Storage temperature

-10…50

0

C

Storage humidity

0…90%RH (no condensation)

Dimensions

112×51×28 mm

Weight

80g

DELIVERY PACKAGE

Coating thickness gauge  - 1 pc.

Metal plate (aluminum, iron) – 2 pcs.

Film reference samples – 5 pcs.

Batteries (1.5V AAA) – 2 pcs.

USB cable – 1 pc.

User manual – 1 pc.

CD-disk – 1 pc.

Hard case – 1 pc.

INSERT/REPLACE BATTERIES

Use a screwdriver to loosen the screw on the battery cover and then remove it. Install the batteries, 

observing polarity. Put the battery cover back and use a screwdriver to tighten the screw. Use alkaline 

batteries only, both batteries must be of the same brand with the same charge level. Charge level is 
shown on display. Replace batteries when you see symbol                   on the display.

SWITCH ON/SWITCH OFF

Short press button            to switch on the device. After switching on the device performs self-diagnosis 
– “Self Test” is shown on the display. After the self-diagnosis is over the device is ready for work.

1

4
6

10

8

9

3
5
7

2

2

3

4

5
6

7
8
9

1

Short press button               to switch off the device.

DISPLAY BACKLIGHT

After switching on the device, the backlight is on automatically. Short press button         to switch on/

off the backlight.

MEASURING UNITS

Depending on the measuring result the device automatically switches between 2 measuring units - µm 

and mm. If the measurement result is within the range 0…999 µm, the device displays the result in 

“µm”. if the measuring result is ≥1000 µm, the device displays the result in “mm”.

SOUND INDICATION FOR MEASUREMENTS OUT OF THE RANGE 

Short press button 

ZERO/CAL 

to open the menu. Press buttons       and      to 

select  

“ALARM” (Sound indication) 

and press button

 OK

Press buttons           and           adjust the maximal 

(High)

 and minimal 

(Low)

 

coating thickness value. If measurement result will be out of adjusted range, 
the device will emit sound signal. Press button 

OK

 to confirm the setting and 

return to the previous section. To exit the menu press button 

ESC

 required 

number of times.

SENSOR

3 methods of measurement are available. The method if set in the following way:
Short press button 

ZERO/CAL 

to open the menu. Press buttons            and       to select

 “MODE”

 and 

press button  

OK

. Press buttons             and           to select 

“SENSOR”

 and press button 

OK

 . 

Press button          and            to select the method of measurement and press button  

OK

  to confirm:

1) Automatic 
The device automatically selects the appropriate mode (magnetic or eddy current) and measures 
according to different surface types (ferrous and non-ferrous metals).
2) Magnetic
This method is intended to measure the coating thickness on a magnetic surface only (ferrous metals).
3) Vortex
This method is intended to measure the coating thickness on a non-magnetic surface (non-ferrous 
metals) only.

GROUPS OF MEASUREMENTS

Short press button 

ZERO/CAL

 to open the menu. Press buttons           and             to select 

“MODE”

 

and press button 

OK

 . Press buttons          and          to select 

“GROUP” (Groups of measurements)

 and 

press button 

OK

 . 

Press buttons           and          to select required group:

1) DIR (single)
This group stores the last 80 measurements. After the device is switched off, these measurements 
will be deleted.
2) GEN 1-4 (group)
Each of these 4 groups stores the last 80 measurements, which will be stored in memory even after the 
device is switched off and on again.

Press button

 OK

 to confirm the setting. To exit the menu press button 

ESC

 required number of times. 

MEASUREMENTS

The device can perform 2 types of measurement:

1) Single measurement 

In single measurement the device makes the first measurement and the result is fixed on the display.

2) Continuous measurement

This mode is used for continuous measurement without removing the sensor from the surface. The 
measurement results are displayed dynamically on the display until the device is removed from the 
surface.
Continuous measurement mode is set by default.
Short press button  

ZERO/CAL

 to open the menu. Press buttons               and           to select 

“MODE”

 and 

press button  

OK

 . Press buttons               and           to select  

“MEASURE”

 

(Type of measurement)

. Press 

buttons          and        to select the type of  measurement – 

“Single”

 or 

“Continuous”

 and press button  

OK 

to confirm. To exit the menu press button 

ESC 

required number of times.

Before starting the measurement, place the device on an open space and ensure that the sensor is 
removed from any metal objects.

Summary of Contents for Paint PRO

Page 1: ...on the battery cover and then remove it Install the batteries observing polarity Put the battery cover back and use a screwdriver to tighten the screw Use alkaline batteries only both batteries must b...

Page 2: ...lts will be displayed in the program Attention the program displays only the results of group measurements Data downloading CARE AND MAINTENANCE Attention This device is a precision instrument and req...

Page 3: ...ppe abzudrehen dann nehmen Sie sie ab Achten Sie dabei auf die richtige Polung Stellen Sie die Abdeckklappe zur ck und ziehen Sie die Schrauben mit Hilfe des Schraubendrehers an Setzen Sie nur Alkali...

Page 4: ...gen angezeigt Data downloading PFLEGE UND BEDIENUNG Vorsicht Dieses Instrument ist ein pr zises Ger t und muss stets vorsichtig behandelt werden Die Beachtung der folgenden Vorschriften verl ngert die...

Page 5: ...5 Language 7 Recovery 0 1500 1 0 999 0 01 1000 3 2 0 5 1 5 25 6 V 3 2 x 1 5 AAA 0 450 C 0 90 RH 10 500 C 0 90 RH 112 51 28 80 1 2 5 1 5 AAA 2 USB 1 1 CD 1 1 Self Test 1 4 6 10 8 9 3 5 7 2 2 3 4 5 6 7...

Page 6: ...OK ESC ZERO CAL DELETE OK OK ESC ZERO CAL RECOVERY OK Yes OK 5 ZERO CAL 50 m 100 m 250 m 500 m 1000 m ZERO CAL CALIBRATION 0 OK 3 OK Success ESC 50 OK 50 m 3 OK Success ESC 100 m 250 m 500 m 1000 m D...

Page 7: ...omoc wkr taka poluzowa ruby pokrywy baterii i zdj pokryw baterii Baterie nale y instalowa zgodnie z biegunowo ci Za o y pokryw baterii i dokr ci ruby rubokr tem U ywaj tylko baterii alkalicznych obie...

Page 8: ...K na urz dzeniu Je li po czenie pomi dzy urz dzeniem a programem zosta o pomy lnie nawi zane w prawym g rnym rogu wy wietlacza pojawi si nast puj cy symbol USB W programie nacisn na przycisk Za adowa...

Reviews: