background image

4

Introduction

Introduction

1.1 

Notes on the addendum manual

This manual is an addendum for the installation of the optional conductivity monitoring system for the 

Condair ME Control and must be read in conjunction with the installation manual and operation manual 

for Condair ME Control. 

This addendum manual has been written to ensure the safe use, performance and longevity of the 

equipment and is intended for use by engineers and properly trained technical personnel. Please read 

this manual thoroughly before installing the optional conductivity sensor.

If you have questions after reading this documentation, please contact your Condair representative. 

They will be glad to assist you.

Symbols used in this manual

CAUTION!

The catchword “CAUTION” used in conjunction with the caution symbol in the circle designates notes 

in this manual that, if neglected, may cause 

damage and/or malfunction of the unit or other mate-

rial assets

WARNING!

The catchword “WARNING” used in conjunction with the general caution symbol designates safety 

and danger notes in this manual that, if neglected, may cause 

injury to persons

.

DANGER!

The catchword “DANGER” used in conjunction with the general caution symbol designates safety and 

danger notes in this manual that, if neglected, may lead to 

severe injury or even death of persons

.

Safekeeping

Please safeguard this addendum manual in a safe place, where it can be immediately accessed. If the 

equipment changes hands, the documentation must be passed on to the new operator. 
If the documentation gets misplaced, please contact your Condair representative.

Language versions

This addendum manual is available in various languages. Please contact your Condair representative 

for information.

Summary of Contents for ME series

Page 1: ... ADDENDUM MANUAL Adiabatic air humidification air cooling system Conductivity Monitoring Option for Condair ME Control This manual must be read in conjunction with Condair ME Control installation manual and operation manual READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...a of Condair Plc Neither this document nor the information contained herein shall be reproduced used or disclosed to others without the written authorisation of Condair Plc except to the extent required for installation or maintenance of recipient s equipment Liability Notice Condair Plc does not accept any liability due to incorrect installation or operation of the equipment or due to the use of ...

Page 3: ...al 4 2 For your safety 5 3 System overview Principle of Operation 7 4 Installation work 8 4 1 Installing the conductivity sensor 8 4 2 Mounting the conductivity monitoring board and connecting the sensor cable 10 5 Configuration 12 6 Conductivity sensor spare parts 13 ...

Page 4: ...n conjunction with the caution symbol in the circle designates notes in this manual that if neglected may cause damage and or malfunction of the unit or other mate rial assets WARNING The catchword WARNING used in conjunction with the general caution symbol designates safety and danger notes in this manual that if neglected may cause injury to persons DANGER The catchword DANGER used in conjunctio...

Page 5: ...ontrol are familiar and comply with the appropriate local regulations on work safety and the prevention of accidents Intended use The conductivity monitoring system is intended exclusively for conductivity measuring of the water in the water tank of the Condair ME Control Any other type of application without the written consent of the manufacturer is considered as not conforming with the intended...

Page 6: ... the owner without delay and to secure such systems against acci dental power up Prohibited modifications to the unit No modifications must be undertaken on the conductivity sensor without the express written consent of the manufacturer For the replacement of defective components use exclusively original accessories and spare parts available from your Condair representative ...

Page 7: ... and controls the conductivity and the temperature of the water in the tank The conductivity monitoring system can be set up with the help of the control software to dilute the tank water when the conductivity or the temperature of the water in the tank reaches a specific level When this occurs the drain pump of the Condair ME Control starts to drain the tank and the inlet valve opens to fill the ...

Page 8: ...tching on 2 Remove the blanking plug from the conductivity sensor port on the top of the hydraulic module if applicable If the Condair ME Control is over 3 m wide and has 6 or 7 stages of control it will have two hydraulic modules in this situation only one conductivity probe is required and it can be installed in either hydraulic module 3 Ensure that the spacer and the O ring are present on the c...

Page 9: ...ll feed through that was provided with the Condair ME Control humidifier if the duct wall feed through was installed other wise a suitable cable feed through must be installed and sealed by the customer 7 Secure sensor cable with cable ties at suitable intervals along the cable run to the Condair ME control unit Note ensure sensor cable is placed in such a way that the insulation is not damaged by...

Page 10: ...Electronic components are very sensitive to electrostatic discharge Before proceeding with the next step appropriate measures ESD protection must be taken to prevent damage to electronic components 3 Open the control unit inner door 4 Fix conductivity monitoring control board to the driver board in socket EXT 1 using the four screws supplied Fig 3 Mounting the conductivity monitoring control board...

Page 11: ...two prong key into the ferrite body 8 Unplug the terminal from the conductivity monitoring control board 9 Position the snap ferrite as close as possible to the terminal then wrap the cable through the ferrite 3 times and close the snap ferrite see Fig 4 10 Plug the terminal back into the conductivity monitoring control board Fig 4 Wiring diagram conductivity sensor 11 Ensure the cable between the...

Page 12: ...ure controlled dilution cycle must be set in the user level of the control software Configuration process Settings for conductivity controlled dillution cycle Password 8808 Set Mode to Condu Limit Set Dilution µS Limit to desired value Settings for temperature controlled dillution cycle Password 8808 Set Mode to H2O Temp Set Dilution H2O Temp to desired value ...

Page 13: ...efective parts in accordance with your local recycling laws and regulations Waste electrical and electronic equipment may contain hazardous substances which if not treated properly can be harmful to the environment and human health Specific treatment of waste electrical and electronic equipment is therefore essential Screw on connecting cable 10 m Conductivity sensor Snap ferrite Conductivity moni...

Page 14: ...Notes ...

Page 15: ......

Page 16: ...Condair Plc Artex Avenue Rustington Littlehampton West Sussex BN16 3LN UK TEL 44 0 1903 850 200 FAX 44 0 1903 850 345 www condair co uk CONSULTING SALES AND SERVICE ...

Reviews: