For your safety

For your safety

General

Every person working with the conductivity monitoring system and the Condair ME Control must have 

read and understood this addendum manual, and the Condair ME Control installation manual and op-

eration manual, before carrying out any work.

Knowing and understanding the contents of the manuals is a basic requirement for protecting the person-

nel against any kind of danger, to prevent faulty operation, and to operate the unit safely and correctly.
All ideograms, signs and markings applied to the unit must be observed and kept in readable state.

Qualification of personnel

All work described in this addendum manual 

may only be carried out by specialists who are well 

trained and adequately qualified and are authorised by the customer

.

For safety and warranty reasons any action beyond the scope of this manual must only be carried out 

by personnel with appropriate industry recognised qualifications or training.
It is assumed that all persons working with the conductivity monitoring system and the Condair ME 

Control are familiar and comply with the appropriate local regulations on work safety and the prevention 

of accidents. 

Intended use

The conductivity monitoring system is intended exclusively for conductivity measuring of the water in the 

water tank of the Condair ME Control. Any other type of application, without the written consent of the 

manufacturer, is considered as not conforming with the intended purpose and may lead to the Condair 

ME Control becoming dangerous.

Operation of the equipment in the intended manner requires 

that all the information contained in 

this addendum manual as well as in the Condair ME Control installation manual and operation 

manual are observed (in particular the safety instructions)

.

Danger that may arise from the Condair ME Control

DANGER!

Risk of electric shock!

The control unit of the Condair ME Control contains live mains voltage. Live parts may be exposed 

when the control unit is open. Touching live parts may cause severe injury or danger to life.
Prevention:

 Before commencing any work on the conductivity monitoring system and the control unit 

disconnect the mains supply voltage to the control unit via the electrical isolator in the mains supply 

line, and secure electrical isolator in “Off” position against inadvertent switching on.

Summary of Contents for ME series

Page 1: ... ADDENDUM MANUAL Adiabatic air humidification air cooling system Conductivity Monitoring Option for Condair ME Control This manual must be read in conjunction with Condair ME Control installation manual and operation manual READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...a of Condair Plc Neither this document nor the information contained herein shall be reproduced used or disclosed to others without the written authorisation of Condair Plc except to the extent required for installation or maintenance of recipient s equipment Liability Notice Condair Plc does not accept any liability due to incorrect installation or operation of the equipment or due to the use of ...

Page 3: ...al 4 2 For your safety 5 3 System overview Principle of Operation 7 4 Installation work 8 4 1 Installing the conductivity sensor 8 4 2 Mounting the conductivity monitoring board and connecting the sensor cable 10 5 Configuration 12 6 Conductivity sensor spare parts 13 ...

Page 4: ...n conjunction with the caution symbol in the circle designates notes in this manual that if neglected may cause damage and or malfunction of the unit or other mate rial assets WARNING The catchword WARNING used in conjunction with the general caution symbol designates safety and danger notes in this manual that if neglected may cause injury to persons DANGER The catchword DANGER used in conjunctio...

Page 5: ...ontrol are familiar and comply with the appropriate local regulations on work safety and the prevention of accidents Intended use The conductivity monitoring system is intended exclusively for conductivity measuring of the water in the water tank of the Condair ME Control Any other type of application without the written consent of the manufacturer is considered as not conforming with the intended...

Page 6: ... the owner without delay and to secure such systems against acci dental power up Prohibited modifications to the unit No modifications must be undertaken on the conductivity sensor without the express written consent of the manufacturer For the replacement of defective components use exclusively original accessories and spare parts available from your Condair representative ...

Page 7: ... and controls the conductivity and the temperature of the water in the tank The conductivity monitoring system can be set up with the help of the control software to dilute the tank water when the conductivity or the temperature of the water in the tank reaches a specific level When this occurs the drain pump of the Condair ME Control starts to drain the tank and the inlet valve opens to fill the ...

Page 8: ...tching on 2 Remove the blanking plug from the conductivity sensor port on the top of the hydraulic module if applicable If the Condair ME Control is over 3 m wide and has 6 or 7 stages of control it will have two hydraulic modules in this situation only one conductivity probe is required and it can be installed in either hydraulic module 3 Ensure that the spacer and the O ring are present on the c...

Page 9: ...ll feed through that was provided with the Condair ME Control humidifier if the duct wall feed through was installed other wise a suitable cable feed through must be installed and sealed by the customer 7 Secure sensor cable with cable ties at suitable intervals along the cable run to the Condair ME control unit Note ensure sensor cable is placed in such a way that the insulation is not damaged by...

Page 10: ...Electronic components are very sensitive to electrostatic discharge Before proceeding with the next step appropriate measures ESD protection must be taken to prevent damage to electronic components 3 Open the control unit inner door 4 Fix conductivity monitoring control board to the driver board in socket EXT 1 using the four screws supplied Fig 3 Mounting the conductivity monitoring control board...

Page 11: ...two prong key into the ferrite body 8 Unplug the terminal from the conductivity monitoring control board 9 Position the snap ferrite as close as possible to the terminal then wrap the cable through the ferrite 3 times and close the snap ferrite see Fig 4 10 Plug the terminal back into the conductivity monitoring control board Fig 4 Wiring diagram conductivity sensor 11 Ensure the cable between the...

Page 12: ...ure controlled dilution cycle must be set in the user level of the control software Configuration process Settings for conductivity controlled dillution cycle Password 8808 Set Mode to Condu Limit Set Dilution µS Limit to desired value Settings for temperature controlled dillution cycle Password 8808 Set Mode to H2O Temp Set Dilution H2O Temp to desired value ...

Page 13: ...efective parts in accordance with your local recycling laws and regulations Waste electrical and electronic equipment may contain hazardous substances which if not treated properly can be harmful to the environment and human health Specific treatment of waste electrical and electronic equipment is therefore essential Screw on connecting cable 10 m Conductivity sensor Snap ferrite Conductivity moni...

Page 14: ...Notes ...

Page 15: ......

Page 16: ...Condair Plc Artex Avenue Rustington Littlehampton West Sussex BN16 3LN UK TEL 44 0 1903 850 200 FAX 44 0 1903 850 345 www condair co uk CONSULTING SALES AND SERVICE ...

Reviews: