USER RESPONSIBILITY

Service to this product should only be performed by CONCOA or an authorized CONCOA agent.  Requests 
for service may be made through CONCOA CUSTOMER SERVICE at 1-800-225-0473.  Written 
requests may be made using CONCOA’s FAX number at 1-757-422-3125 or CONCOA’s E-MAIL at 
[email protected]

CONCOA accepts no responsibility for damage or injury if this product is modified in any way.

CONCOA assumes/accepts no liability or responsibility for damage to individuals or equipment that may 
occur when using this product.

SAFETY

THIS PRODUCT IS NOT INTENDED FOR USE WITH TOXIC GASES, FLAMMABLE GASES OR 
CORROSIVE GASES.

Basic safety precautions must be followed to reduce the risk of fire, electrical shock or injury.

·   Connect the IntelliSwitch to the correct line voltage.  A label on the product identifies what voltage it is 

wired for.  CONNECTION TO AN INCORRECT VOLTAGE CAN CAUSE SERIOUS DAMAGE 
TO THE PRODUCT AND WILL VOID ANY WARRANTY.

·   While the IntelliSwitch Switchover is dust and moisture resistant, it is NOT water-proof or completely 

sealed.  It should be installed where it will not be subjected to rain or high concentrations of dust.  Never 
pour or spray liquids directly onto the product.

·   Install IntelliSwitch where the ambient temperature range is between 0° F and 140° F.

·   Do not install this product in a hazardous environment.

· 

If product appears damaged in any way, do not use and request service from CONCOA.

·   Do not attempt to operate the IntelliSwitch with the front panel off.

· 

Consult the cylinder distributor for the proper use of cylinders and for any restrictions on their use (such 
as flow rate and temperature requirements).

· 

Store cylinders with valve caps screwed on, and chain cylinders to a supporting wall or column.

· 

Handle cylinders carefully and only with valve caps screwed on.  The cap will reduce the chance that the 
cylinder valve will break off if the cylinder is accidentally dropped or falls over.  The cap also protects 
the cylinder valve from damage to screw threads, which could cause leaky connections.

· 

All manifolds used with flammable gases should be provided with approved flashback arrestors to stop 
any burning gas in the pipeline from getting back to the manifold or cylinders. 

· 

No smoking should be permitted near oxygen, nitrous oxide, any other oxidizer, flammable gases, or 
flammable mixtures, or in areas where cylinders are stored.

· 

Where an oxidizer (such as nitrous oxide or oxygen) is used, the manifold and cylinders must be kept 
clean.  No oil, grease, or combustible substances should come in contact with oxygen or nitrous oxide 
storage or handling equipment.  Such materials in contact with oxygen or nitrous oxide are readily 
ignitable and, when ignited, will burn intensely.

· 

Never lift gas cylinders with a magnetic lifting device.

· 

Never use an open flame when leak testing. 

· 

Always open valves slowly when high-pressure gases are being used.

Summary of Contents for INTELLISWITCH

Page 1: ...ion of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instr...

Page 2: ...o drop below the switching point even if there is plenty of gas left in the cylinder When a typical switchover enters such a state two undesirable situations may occur First the system may switch to t...

Page 3: ...PSI This value is factory set but can be changed in the field To change this value refer to the section on changing the switchover pressure Manual Bank Switching It is possible to manually change the...

Page 4: ...nment If product appears damaged in any way do not use and request service from CONCOA Do not attempt to operate the IntelliSwitch with the front panel off Consult the cylinder distributor for the pro...

Page 5: ...and Welding Processes same address as 2 4 CONCOA publication ADE 872 Safety Precautions in Welding and Cutting 5 Local Ordinances 6 O S H A Standard 29 CFR 7 C G A Pamphlet C 4 American National Stan...

Page 6: ...n external air driven IntelliSwitch turn the air source on at this time Finally connect AC power to the IntelliSwitch The system is factory set to operate at either 115VAC 60hz or 230 VAC 60hz Connect...

Page 7: ...s being used by each side All switching is automatic If the primary side drops below the set switchover point the system will transfer to the reserve side and the status lights will indicate the trans...

Page 8: ...tch will redirect itself to draw the pressure down through the delivery stream Once the pressure reaches a normal value it will return to drawing from the previous side Bank Selection The Bank Select...

Page 9: ...9 Figure 2...

Page 10: ...d removing the nut Using a Phillips screwdriver remove the 4 screws and washers holding the front panel Unscrew the nut on the outlet pressure adjustment regulator being careful not to allow the front...

Page 11: ...6 Switchover pressure set 6 32 7 Switchover pressure set 7 64 8 Switchover pressure set 8 128 9 Switchover pressure set 9 256 10 Reserved 11 PSI units set if SW1 11 and SW2 11 both not set units MPA O...

Page 12: ...itches REMOVE AC power from the system Remove the knob on the outlet pressure adjustment regulator by carefully lifting the center label on the knob and removing the nut Using a Phillips screwdriver r...

Page 13: ...nger tight Re install the 4 screws and washers holding the front panel Attach the knob to the regulator using the nut and reapply the label The nut holding the knob should be tightened securely Re app...

Page 14: ...is also possible to purchase a ready made cable assembly Contact your local CONCOA Distributor or call 1 800 225 0473 for information Cut the 4 conductor cable to length Remove the outer jacket of the...

Page 15: ...low Using the pin assignments shown in Table 7 and the connector views in Figure 6 and Figure 7 solder the wires to the appropriate pins After soldering is complete attach the connector cover to the 2...

Page 16: ...regulator There is a pressure reading on the left inlet display and no pressure on the right inlet display or outlet display In a system using delivery process gas activation the right side must be p...

Page 17: ...e valve that controls flow from the left inlet to ON This helps determine if there is gas flow from the left side If gas is not flowing during this test check that the cylinder s is turned on and full...

Page 18: ...s a liquid cylinder to recover its pressure to a predetermined value Hysteresis Pressure above the set switchover pressure point as viewed in Test 9 This number is factory set between 0 and 60 minutes...

Page 19: ...ON OFF OFF ON 89 ON OFF ON ON OFF OFF ON 26 OFF OFF ON ON OFF ON OFF 90 ON OFF ON ON OFF ON OFF 27 OFF OFF ON ON OFF ON ON 91 ON OFF ON ON OFF ON ON 28 OFF OFF ON ON ON OFF OFF 92 ON OFF ON ON ON OFF...

Page 20: ...to the IntelliSwitch contact your local Distributor or CONCOA Customer Service at 1 800 225 0473 Please fill in the Self Test Worksheet form included in this manual before contacting CONCOA for assist...

Page 21: ...qqqq qqqq 3 Software Revision qqq qqqq qqqq 4 Transducer Test qqq qqqq qqqq 9 DIP Switch Value qqq qqqq qqqq 10 Button Test qqq Left Source Select qqqq qqqq Right Source Select qqqq qqqq Bank Select q...

Page 22: ...22 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 23: ...e other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s sol...

Page 24: ...ADI 9502 A Certified ISO 9001 2000 Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com...

Reviews: