![Concoa INTELLISWITCH Installation And Operating Instructions Manual Download Page 12](http://html1.mh-extra.com/html/concoa/intelliswitch/intelliswitch_installation-and-operating-instructions-manual_2651342012.webp)
12
13
Table 3 — Typical Switchover Pressure DIP Switch Settings
PSI
SW1-9
SW1-8
SW1-7
SW1-6
SW1-5
SW1-4
SW1-3
SW1-2
SW1-1
75
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
100
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
125
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
135
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
150
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
175
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
200
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
225
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
250
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
275
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
300
ON
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
325
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
350
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
375
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
400
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
425
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
450
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
475
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
500
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
Units of Measure
The IntelliSwitch is capable of displaying pressure in PSI, BAR or MPA. The units of measure are factory set
to PSI. Units of measure may be changed by setting DIP Switches 11 and 12 on the electronic circuit board
inside the system.
To access the DIP switches, REMOVE AC power from the system. Remove the knob on the outlet pressure
adjustment regulator by carefully lifting the center label on the knob and removing the nut. Using a Phillips
screwdriver, remove the 4 screws and washers holding the front panel. Unscrew the nut on the outlet pressure
adjustment regulator being careful not to allow the front panel to fall. There are two long studs attached to
the inside of the front panel that will allow hanging of the panel to the bottom of the enclosure.
Using Table 4 and Figure 3, set the switchover pressure DIP switches to the desired value. When completed,
place the front panel back into place being careful not to pinch any wires. Attach the large nut to the outlet
pressure adjustment regulator first. This only needs to be finger tight. Re-install the 4 screws and washers
holding the front panel. Attach the knob to the regulator using the nut and reapply the label. The nut
holding the knob should be tightened securely.
Re-apply AC power.
Table 4 — Units of Measure
Units of Measure
SW1-11
SW1-12
PSI
ON
OFF
BAR
OFF
ON
MPA
OFF
OFF
The indicator lights on the front panel will show the units selected. For PSI and BAR the light will be ON.
If MPA is selected neither the PSI or BAR light are ON signifying MPA.
Summary of Contents for INTELLISWITCH
Page 9: ...9 Figure 2...