42
PDV 7160
EN
• Water volume
Use the smallest volume of water necessary. This way you can save energy. Also, your food will retain vitamins
and minerals.
• Lowering the temperature
Use timely setting of a lower temperature.
Thermocouple protection preventing gas outflow if the burner is extinguished
This is a thermoelectric cell located near the burner that controls the flame on the basis of emitted heat, and in the
event of accidental blowing out of the flame it will close the gas feed for the burner.
Burner jet exchange
If you want to use the appliance on liquid propane-butane or propane, the jets have to be replaced before the
operation (depending on the model these are supplied or can be purchased).
Spotřebič je standardně dodáván s tryskami na zemní plyn. Jets on liquid gas proban butane or propan
butane for CZ and SK region are enclosed in the unit packaging.
For PL region it´s possible to buy jets for liquid propan butane or propan butane from the authorised
dealer.
Only an authorized service centre can perform the replacement of jets and setting of the minimum flame!
Procedure:
1. Remove the burner grates
2. Remove the flame diffusers and their caps.
3. Unscrew and remove the gas jets using box spanner No. 7 and replace with new ones according to the gas
type.
4. Follow reverse steps to re-assemble the burners.
Minimum flame setting
The minimum flame setting is required in some cases following the replacement of the burner jets.
1. Light the burner.
2. Pull upward and remove the control knob.
3. Adjust the flame size using a screwdriver. Depending on the model the adjusting screw is located in the control
valve shaft or next to it (Fig. 4a, 4b).
Minimum flame height should be 3 - 4 mm. When using propane-butane drive the screw all the way down.
Fig. 4a