EXAMPLE WIRING DIAGRAM
Filename:
20101129-E+PIR Exagon & IAS-v4
Page
1
of
1
Project:
Wiring Diagram Update
Created by:
Hallwood
Checked by:
Max Danesfeldt
Date:
29 Nov 2010
Date:
25 Feb 2011
E+ with PIR, Exagon and IAS
PIR
12v
0v
Trigger
Trigger
Tamper
Tamper
E+ Unit
12v
0v
8 Xt Tam
Exagon
7 Xt Tam
6 Hold Off
Spare
5 Hold Off
Spare
Trigger
4 Trigger
Trigger
3 Trigger
Low
2 Set
Low
1 Set
Ready
Ready
Aux n/c
0v
Aux c
12v
Aux n/o
Verify n/c
Verify c
Verify n/o
UPS n/c
UPS c
UPS n/o
LowFlu n/c
LowFlu c
LowFlu n/o
Ready n/c
Ready c
Ready n/o
Notes:
Take care with Trigger and Set connections.
Do not cross connect -ve and +ve rails together.
PCB max output current is 250mA.
Alarm Panel
Set
Set
Intruder
Intruder
To simplify this schematic the connection pins may
not necessarily be shown in the same order as the
relevant unit.
Where possible use yellow for -ve connections and
blue for +ve connections.
Alarm Panel contacts should be clean relay closed
pairs energising open on set / intruder.