STEP 4 - WIRING
ceiling
false roof
Timing Card
15S
1M
2M
3M
4M
5M
6M
Tamper (PIR)
Tamper (PIR)
12-Volt (PIR/I’face)
0-Volt (PIR/I’face)
N/C (PIR)
N/C (PIR)
1. Trigger (input)
Trigger (input)
2. Ready (output)
Ready (output)
3. Low fluid (output)
Low fluid (output)
Feed wires through the grips on the top of the
unit. Remove butterfly nut and wiring case to
expose a bank of connector blocks.
Carefully connect the wires to the
corresponding connector block.
If no PIR is used, link both Tamper (PIR).
Finally, the on board timer should be set for an
appropriate period - subject to the volume of
space to be protected.
Notes:
1. Trigger Input = N/C opening in ‘Alarm’
2. Ready Output = N/C when ‘Ready’
3. Low Fluid = N/O closing when ‘Low Fluid’
Timer:
Fully anticlockwise - 15 secs
Fully clockwise - 6 minutes