DeviceMaster LT User Guide
: 2000586
Rev. B
Managing the DeviceMaster LT - 71
Updating Firmware Across WANs (Windows)
2.
Make sure that you have downloaded the latest SocketServer version from:
ftp://ftp.comtrol.com/dev_mstr/LT/software/socketserver
You may want to place SocketServer in the same directory as the
Tftpd
server.
3.
Optionally, rename the
SocketServer-
x.xx
.bin
file (where
x.xx
is the version
number) to
1.bin
to make the following steps easier.
4.
If necessary, open PortVision DX:
Start >Program > Comtrol > PortVision DX >
PortVision DX
or the desktop shortcut.
5.
Change the Bootloader Timeout value to 60 seconds.
a.
Right-click the DeviceMaster LT in the
Device List
pane for which you
want to upload the latest SocketServer and click
Properties.
b.
Change the
Bootloader Timeout
value to 60, click
Apply Changes
, and then
Close
.
Note:
If the PuTTY screen flashes in the background and does not appear
as shown above, make sure that
Enable Telnet/ssh
has not been
disabled in SocketServer. To check this, return to PortVision DX,
right-click the DeviceMaster LT in the Device List pane, and click
Webpage
. Click the
Security
tab and if necessary, verify that the
Enable Telnet/ssh
option is enabled.