SDM-9000 Satellite Modem
Maintenance
Rev. 4
6–19
6.2.2.2 Fault/Alarm Analysis
6.2.2.2.1 Modulator Faults
Fault/Alarm
Possible Problem and Action
IF SYNTHESIZER
Modulator IF synthesizer is faulted.
This is considered a major fault and will turn off the modulator
output. Return the modulator module for repair.
DATA CLOCK ACT
Transmit data clock activity alarm.
This fault is not considered a major fault and will not turn off the
modulator output. The problem is most likely on the interface
card or external to the modem. Use the baseband loopback and
interface loopback test modes for checking the interface. Ensure
the incoming data clock is present at the modem DATA I/O
connector. If data and clock are present at the DATA I/O, then
replace the interface card to clear the alarm and return the card
for repair.
DATA CLOCK SYN
Transmit data clock synthesizer fault.
This fault is an indication that the internal clock VCO has not
locked to the incoming data clock, or the internal clock
synthesizer has not locked to the internal reference. This is
considered a major fault and will turn off the modulator output.
Ensure the proper data rate has been set up and selected, and
the incoming data rate matches the modem selections.
I CHANNEL
Activity fault for the I channel digital filter.
This alarm is considered a major fault and will turn off the
modulator IF output. An alarm in this position indicates either a
fault in the scrambler, or if the scrambler is disabled, it indicates a
loss of incoming data. If the fault is active with the scrambler
turned off, check for input data at the DATA I/O connector. If data
is present, replace the interface card to clear the fault and return
the interface card for repair. If the fault is active with the
scrambler turned on, replace the modulator card and return it for
repair.
Q CHANNEL
Activity fault for the Q channel digital filter. Use the I channel
procedure above.
AGC LEVEL
Output power AGC level fault.
Indicates the level at the modulator output is not the programmed
level. Replace the modulator card and return it for repair.
INTERNAL SCT SYN
Internal TX data clock synthesizer fault.
The SCT has failed to lock to the internal reference. Replace
modulator board.
EXT REF ACT
External reference activity alarm.
Activity alarm for the external reference clock. Indicates clock
reference not detected.
Summary of Contents for SDM-9000
Page 2: ......
Page 5: ...8 Mbit s w IDR Figure 1 7 16QAM BER Performance Curves with Reed Solomon Filename T_ERRATA 3...
Page 8: ......
Page 27: ...SDM 9000 Satellite Modem Introduction Rev 4 1 5 Figure 1 3 SDM 9000 Block Diagram...
Page 42: ...Introduction SDM 9000 Satellite Modem 1 20 Rev 4 This page is intentionally left blank...
Page 64: ...Configuration SDM 9000 Satellite Modem 3 6 Rev 4 JP1 Figure 3 4 Interface PCB AS 3971...
Page 65: ...SDM 9000 Satellite Modem Configuration Rev 4 3 7 Figure 3 5 Interface PCB AS 4477...
Page 66: ...Configuration SDM 9000 Satellite Modem 3 8 Rev 4 JP1 JP6 JP7 Figure 3 6 Interface PCB AS 5618...
Page 70: ...Configuration SDM 9000 Satellite Modem 3 12 Rev 4 Figure 3 7 Nyquist Filter Installation...
Page 83: ...SDM 9000 Satellite Modem Operation Rev 4 4 9 This page is intentionally left blank...
Page 87: ...SDM 9000 Satellite Modem Operation Rev 4 4 13 This page is intentionally left blank...
Page 104: ...SDM 9000 Satellite Modem Operation Rev 4 4 31 This page is intentionally left blank...
Page 107: ...Operation SDM 9000 Satellite Modem 4 34 Rev 4 This page is intentionally left blank...
Page 124: ...SDM 9000 Satellite Modem Operation Rev 4 4 51 Figure 4 17 RF Loopback Figure 4 18 IF Loopback...
Page 150: ...Theory of Operation SDM 9000 Satellite Modem 5 22 Rev 4 Figure 5 6 Interface Block Diagram...
Page 158: ...Theory of Operation SDM 9000 Satellite Modem 5 30 Rev 4 This page is intentionally left blank...
Page 186: ...Maintenance SDM 9000 Satellite Modem 6 28 Rev 4 This page is intentionally left blank...
Page 218: ...Options SDM 9000 Satellite Modem A 32 Rev 4 This page is intentionally left blank...
Page 242: ...Remote Control Operation SDM 9000 Satellite Modem B 24 Rev 4 ref SE_ command...
Page 254: ...Glossary SDM 9000 Satellite Modem g 6 Rev 4 This page is intentionally left blank...
Page 256: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...