R-1170/1270 Redundancy Switch Controllers
Revision 0
Ethernet Interface Operation
5–2
MN-RC-1170/1270
5.2
SNMP Interface
SNMP is an Internet-standard protocol for managing devices over IP networks. An SNMP-managed
network has three key components:
•
The managed device. This includes the RC-1170/1270 Redundancy Switch Controller.
•
The SNMP Agent. This software runs on the RC-1170/1270 Redundancy Switch
Controller. The RC-1170/1270 Redundancy Switch Controller SNMP Agent supports both
SNMPv1 and SNMPv2c.
•
The user-supplied Network Management System (NMS). This software runs on the User
PC.
5.2.1 Management Information Base (MIB) Files
An MIB file is used for SNMP remote management of a unique device, and consist of a tree of
nodes called Object Identifiers (OIDs). Each OID provides remote management of a particular
function. These MIB files should be compiled in a user-supplied MIB Browser or SNMP NMS
server.
In the RC-1170/1270 Redundancy Switch Controller MIB file names, the letter x represents the
revision of the file.
5.2.1.1 CEFD Root MIB File
•
FW10874-2-.mib
•
CEFD MIB file gives the root tree for all CEFD RC-1170/1270 Redundancy Switch
Controller products (PSx) and consists of only the following OID:
o
Name: comtechEFData
o
Type: MODULE-IDENTITY
o
OID: 1.3.6.1.4.1.6247
o
Full path:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtechEFData(6247)
Module: ComtechEFData
5.2.1.2 RC-1170/1270 Redundancy Switch Controller MIB File
•
FW-0021149X_rev111.mib
•
MIB file consists of all of the OID’s for management of the RC-1170/1270 Redundancy
Switch Controller functions.
5.2.1.3 RC-1170/1270 Redundancy Switch Controller Traps MIB File
•
FW-0021148X_rev111.mib
•
Trap MIB file provides SNMPv1 traps common for RC-1170/1270 Redundancy Switch
Controller