LPOD-R Outdoor Amplifier / Block Up Converter
MN-LPODR
Ethernet Interface Operation
Revision 3
4–7
5.
Use the command IPA=xxx.xxx.xxx.xxx.yy, where “xxx.xxx.xxx.xxx” is a
valid IP Address on the network where the unit is to be installed, and “yy”
is the subnet range (typically, yy = 24).
1)
You must assign a unique IP Address for each unit on the network
before connecting to an existing network. The IP Address may need
to be changed from the factory default setting.
2)
Changing the IPA value requires that you cycle power on the unit,
and then start a new Telnet session using the new IP Address.
3)
Loss of the unit’s Management IP Address or the interface access
credentials (i.e., the username/password and SNMP communities)
prohibits M&C of the LPOD-R. Follow the procedures described in
Sect. 2.4.3 Recovering the User Interface Access (in Chapter 2.
SYSTEM CONNECTORS, INSTALLATION,
AND
STARTUP) to restore the
factory default M&C interface access settings.
See the table of Remote Commands and Queries in
Chapter 5. OPTIONAL
SERIAL INTERFACE OPERATION (PS 1, PS 1.5 ONLY)
for detailed
operational information.
4.4.2
HTTP Interface User Login
Do these steps:
1.
From the PC, enter the default IP Address for the LPOD-R (e.g.,
http://192.168.1.4
) into the
Address
area of the browser.
2.
In the Login window, type the
User name
and
Password,
and then click
OK
. The default User Name and Password are both
comtech
.