LBC-4000 L-Band Up/Down Converter System
MN/LBC4000.IOM
Firmware Update
Revision 5
5–5
•
The ‘Summary’ section of the ‘Status | Summary’ page provides
the firmware details – “FW Revision”, “Active Software Image”,
and “Next Reboot Image” – as shown in this example:
2.
Write down your firmware information for further reference or to provide
to Comtech EF Data Product support.
5.2.3.3
Use the Serial Interface to Find the Firmware Information
Chapter 8. SERIAL INTERFACE OPERATION
Use your terminal emulator program to execute remote queries with the
LBC-4000. Use the “FRM” or “FRW” remote query to find the pertinent firmware
information:
•
<DEV/FRM_{cr}
(returns the current (Ethernet-ready) firmwares running under Boot,
Bulk1, and Bulk2 in the form FW-AAAAAAA; B.B.B; DD/MM/YY, where:
o
FW-AAAAAAA = the firmware part number
o
B.B.B = the firmware version number
o
MM/DD/YY = the firmware release date (Month/Day/Year)
•
<DEV/FRW_{cr}
(returns the legacy (Serial operation only) firmwares in the form:
o
BULK=FW/9965X (where X is the Revision Letter)
o
M&C=FW/9966X (where X is the Revision Letter)
o
FPGA=FW/9967X (where X is the Revision Letter)