The voltage appearing on terminals
1
,
2
or
3
depends only on
the system to be controlled, therefore the dimension of the wire to
be used is determined by the type of the device to be controlled.
The length of the wire is of no significance, the receiver unit may
be installed either near the boiler or far away from it.
If the distance between the transmitter and receiver units is too
large due to local circumstances and it makes the wireless (radio-
frequency) connection unreliable, install the receiver unit nearer to
the place of thermostat.
7.2 Putting the receiver unit into operation
Turn on the power supply to the receiver unit. After a few seconds
have elapsed, the wireless (radio-frequency) system (thermostat
and receiver unit) tunes itself to the specified frequency. On trial
press the button of the thermostat several times, until the set
temperature is 2-3°C higher than the temperature of the room.
Following this, the “
HEAT
” icon indicating that the heating is turned
on should appear on the display of the thermostat within a few
seconds.
At the same time, the red LED light on the receiver unit should
switch on to indicate that the receiver unit has received the
command of the transmitter (thermostat).
If it does not happen, the system should be retuned. For this
purpose press the “M/A” button of the receiver unit and keep it
depressed (for approximately 10 seconds) until the green LED
starts flashing. Then press the “
LEARN
” button of the thermostat
located near the battery compartment and keep it depressed (for
approximately 10 seconds) until the green LED stops flashing
and goes out, so that the receiver unit “learns” the safety code of
the transmitter (thermostat). The safety code will not be lost even
during a power outage, the system memorizes it automatically.
ATTENTION:
Pressing the “
LEARN
” button for 10 seconds
generates a new safety code for the thermostat, and the receiver
will recognize it only after a repeated tuning. With this in mind, do
-10 -