TECHNICAL DATA
Technical data of the thermostat (transmitter):
— temperature measurement range:
5 to 35°C
(in 0.1°C increments)
— adjustable temperature range:
10 to 30°C
(in 0.5°C increments)
— temperature measurement accuracy:
±0.5°C
— selectable switching sensitivity:
±0.2/±0.3°C
— defrosting temperature:
+7°C
— storage temperature:
-10°C to +60°C
— power supply voltage:
2x1.5 V AA alkaline batteries
(LR6 type)
— operating frequency:
868.35 MHz
— power consumption:
1.5 mW
— battery lifetime:
approx. 1 year
— dimensions:
112 x 75 x 45 mm
— weight:
154 g
— temperature sensor type:
NTC 10 K
Ω
±1% at 25°C
Technical data of the receiver unit:
— power consumption:
6W
— power supply voltage:
230V AC, 50Hz
— switchable voltage:
24V AC / DC, ÷ 250V AC; 50Hz
— switchable current :
6A (2A inductive load)
— transmission distance:
approx. 50 m in open terrain
— weight:
150g
Total weight of the device: approx. 350 g
(therholder)
The COMPUTHERM Q3 RF type thermostat complies with the
requirements of standards EU EMC89/336/EEC; LVD 73/23/EEC;