unit then fix the back panel to the wall in the vicinity of the boiler 
with the screws provided. Remove the protective carton from the 
contacts to ensure perfect contact. The marks of the connections 
are pressed into plastic above the sensors: 

N

L

1

2

 and 

3

.

230 V mains voltage should be supplied to the receiver unit. We 

recommend using a fixed cable instead of a fork type connection 
for mains connection to avoid any unintentional de-energization of 
the device. We propose to connect the neutral wire of the network 
to point 

N

, while the phase conductor to point 

L

. We propose to 

interpose a switch so that the receiver unit can be de-energized 
if required.

The  receiver  unit  controls  the  boiler  through  a  potential-free 

alternating relay whose connection points are: 

1

 (NO); 

2

 (COM); 

3

 (NC). The connection wires of the boiler should be connected to 

terminals 

1

 (NO) and 

2

 (COM) to control a heating equipment, while 

the connection wires of the cooling equipment should be connected 
to terminals 

2

 (COM) and 

3

 (NC) to control a cooling unit.

ATTENTION!

 The instructions of the manufacturer of the heating 

(cooling) equipment should always be followed!

Heating unit (Boiler)

Rear panel of the 

receiver unit

N

L

(phase)

 - 9 -

~ 230V 

50 to 60 Hz

~ 230V 

50 to 60 Hz

L

N

1 2

COM

NO NC

Summary of Contents for q3rf

Page 1: ...COMPUTHERM Q3 RF wireless radio frequency digital room thermostat Operating Instructions...

Page 2: ...w and above the adjusted temperature respectively and contributes to reduce energy costs while maintaining comfort The device consists of two units One of them is the portable control unit thermostat...

Page 3: ...sensitivity of the thermostat is 0 2 C 0 3 C This means the difference between the adjusted temperature and the actual temperature measured during the switching process For example if the factory def...

Page 4: ...maximum temperature in the room where the room thermostat is to be located otherwise the thermostatic head may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASI...

Page 5: ...t of the Displayed Temperature The unit of measurement of the temperature shown on the LCD display can be selected and set by the central jumper With factory default settings the display shows the tem...

Page 6: ...uble free wireless radio frequency connection both the thermostat and the receiver unit have their own safety codes After installing the receiver unit the two units should be synchronised by pressing...

Page 7: ...rature is displayed 5 Operation of the Installed Thermostat After connecting commissioning and performing basic settings and setting the temperature the thermostat is ready for operation and controls...

Page 8: ...is 1 year The icon alternately replacing the temperature value on the LCD display indicates low battery voltage Replace the batteries whenever the ddd icon indicating low battery voltage appears on t...

Page 9: ...nt N while the phase conductor to point L We propose to interpose a switch so that the receiver unit can be de energized if required The receiver unit controls the boiler through a potential free alte...

Page 10: ...the temperature of the room Following this the HEAT icon indicating that the heating is turned on should appear on the display of the thermostat within a few seconds At the same time the red LED ligh...

Page 11: ...wo units are outside the transmission distance of the wireless radio frequency transmitter thus they have to be placed closer to each other 7 4 Manual control of the receiver unit Pressing the MANUAL...

Page 12: ...ency 868 35 MHz power consumption 1 5 mW battery lifetime approx 1 year dimensions 112 x 75 x 45 mm weight 154 g temperature sensor type NTC 10 K 1 at 25 C Technical data of the receiver unit power co...

Reviews: