Compass 07 172 Manual Download Page 12

12

E

item 07 172 / 07 173

Starter test

Attention! During the starter tests, the load switch must not be turned on. Before the starter tests, it is required to conduct a test 
of the accumulator under load and write down the voltage value. Attention! Is the test of an accumulator under load did not indi-
cate a full capacity of the accumulator, the starter test will not succeed.
The engine of the vehicle should reach its normal working temperature, and then it should be turned off. Connect the tester as in 
the case of testing of an accumulator. Start the engine and observing the indicator write down the voltage value.
Compare the voltage values from the test under load and the starter test, using the following table.

If the observed value is lower than the one indicated in the table, the cranking current is too high. Is may be a result of bad con-
di- tions of the contacts, a damaged starter or engine, or an insufficient capacity of the accumulator.

MAINTENANCE OF THE DEVICE

The device does not require any special maintenance. A dirty housing should be cleaned with a soft cloth or with a compressed 
air jet, whose pressure must not exceed 0.3 MPa.
Check the conditions of the terminals of the conductors before and after each use. Remove any signs of corrosion, which might 
disturb the flow of the electric current. Avoid contamination of the terminals with the electrolyte from the accumulator, since it 
would accelerate the process of corrosion.
The device should be stored in a dry place, away from unauthorised persons, particularly children. Make sure the cables and 
conductors are not damaged during storage.

model 07 172, digital

Press and release the load switch, which will cause a 100 
A current to flow through the load for 10 sec.
If when the load is on the green „OK” diode is lit, the accu-
mulator is loaded to its full capacity. Write down the dis-
played voltage value.
If the yellow „WEAK” diode is lit, but the voltage value shown 
by the indicator is constant, the accumulator is not loaded to 
its full capacity. It is then required to check the capacity of the 
accumulator using other methods, e.g. checking the density 
of the electrolyte with an aerometer.
If the red „BAD” diode is lit and the voltage value is decreas-
ing, it may be necessary to replace the accumulator with a 
new one.

Tests of the charging of the accumulator

ATTENTION! When the engine is operating, the load switch 
must  not  be  turned  on.  Connect  tester  as  in  the  case  of 
testing of an accumulator.
Start the engine and wait until it has reached the normal wor-
king temperature. Maintain the rotation of the engine within 
the range of 1200 – 1500 rpm.
The indicator should show a value within the range of 13.5 - 
15 V. If other values are indicated, the accumulator is not loa-
ded to its full capacity. It is then required to check the capacity 
of the accumulator using other methods, e.g. checking the 
density of the electrolyte with an aerometer.

model 07 173, analogue

Observe the arrow while the load is on. If the arrow is in 
the green area, the accumulator is loaded to its full capaci-
ty. in case of the most popular 12 V accumulators the 
green area of the scale is arranged in steps, depending on 
the cold cranking current of the accumulator (200 - 1000 
A). The parameter of the cold cranking current (CCA) is 
specified in the documentation of the accumulator.
If the arrow is outside the green area, but it does not drop 
towards the lowest value of the scale, the accumulator is not 
loaded to its full capacity. It is then required to check the capa-
city of the accumulator using other methods, e.g. checking 
the density of the electrolyte with an aerometer.

Testing of the charging of the accumulator

ATTENTION! When the engine is operating, the load switch 
must not be turned on. Connect the tester as in the case of 
testing of an accumulator.
Start the engine and wait until it has reached the normal wor-
king temperature. Maintain the rotation of the engine within 
the range of 1200 – 1500 rpm.
Check the indication; if the arrow is within the green area, the 
charging system is working properly.
The arrow in the red area means an incorrect operation of the 
charging system. It may lead to a situation when the accumu-
lator will not reach its nominal capacity.

 

Voltage of the test 

Minimum voltage of the starter test

 

under load 

motor capacity < 3,6 dm3 

motor capacity ≥ 3,6 dm3

 

10,2 V 

8,2 V 

7,7 V

 

10,4 V 

8,7 V 

8,2 V

 

10,6 V 

9,2 V 

8,7 V

 

10,8 V 

9,7 V 

9,2 V

 

11,0 V 

10,2 V 

9,7 V

 

11,2 V 

10,6 V 

10,2 V

 

11,4 V 

11,0 V 

10,6 V

Summary of Contents for 07 172

Page 1: ...C Z t ov tester autobaterie S Z a ov tester autobat rie E Battery tester digitaln digit lny digital analogov anal gov analogue item 07 172 item 07 173...

Page 2: ...hov n je ivotunebezpe n Tester je ur en k pou it uvnit m stnost a je zak z no vystavovat ho p soben vlhkosti v etn atmosf rick ch sr ek V p pad testov n akumul toru p mo ve vozidle p ipojen ho k elekt...

Page 3: ...diska pou it ch elektric k ch za zen Aby se omezilo mno stv odpad je nevyhnutn jejich op tovn vyu it recyklace nebojin formaregenerace Zm natextuatechnick chparametr vyhrazena Zm ny v textu designu a...

Page 4: ...l ku pod ru i kou tento daj nastavit P ipojte svorky testeru k p l m akumul toru a zkont rolujte zdajesvorka testeruozna en ervenoubar vou p ipojen k p lu akumul toru ozna en mu a svorka testeru ozna...

Page 5: ...r je nep stupn nepovolan m osob m a zejm na d tem B hemskladov n dbejtenato abynedo lokpo kozen elektrick chkabel avodi model 07 172 digit ln Test nab jen akumul toru POZOR Kdy je motor nastartovan je...

Page 6: ...s toxick aichvdychovanieje ivotunebezpe n Tester je ur en na pou vanie vn tri miestnost a je zak zan vystavova ho p sobeniu vlhkosti vr tane atmo sf rick ch zr ok V pr pade testovania akumul tora pria...

Page 7: ...rebovan ch elektrick ch zariaden Aby sa obmedzilo mno stvo odpadov je nutn ich op tovn vyu itie recykl ciaaleboin formyregener cie Zmenatextuatechnick chparametrovvyhraden Zmeny v texte dizajne a tech...

Page 8: ...ojte svorky testera ku p lom akumul tora askon trolujte i je svorka testera ozna en ervenou far bou pripojen k p lu akumul tora ozna en mu a svorka testera ozna en iernou farbou k p lu aku mul toraozn...

Page 9: ...te ktor je nepr stupn nepovolan m osob m a najm de om Po asskladova niadbajtenato abynedo lokpo kodeniuelektrick chk blovavodi ov model 07 172 digit ln Test nab jania akumul tora POZOR Ke je motor na...

Page 10: ...nect the terminal of the tester to the terminal of the accumu lator which is not connected to the chassis of the vehicle and then connect the other terminal of the tester to the chassis away fromtheac...

Page 11: ...tuation consistinginevaporationofthefac torypreservativeoftheloadatahightemperature Connect the tester as in the case of testing of an accumula tor model 07 173 analogue Testingofanaccumulator Before...

Page 12: ...thods e g checking the density oftheelectrolytewithanaerometer If the red BAD diode is lit and the voltage value is decreas ing it may be necessary to replace the accumulator with a newone Tests of th...

Reviews: