POST Error Messages
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
F-13
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1787
Slot x drive array
operating in Interim
Recovery Mode. The
following SCSI drive(s)
should be replaced:
SCSI port (y): SCSI ID
(x)
Following a system restart, this message reminds
you that drive x is defective and fault tolerance is
being used. Replace drive x as soon as possible.
A loose or defective cable may also cause this
error.
1788
(1) Slot x drive array
reports incorrect drive
replacement. The
following SCSI drive(s)
should have been
replaced: SCSI port
(y): SCSI ID (x).
The following SCSI
drive(s) were
incorrectly replaced:
SCSI port (y): SCSI ID
(z).
Press the
F1
key to
continue – drive array
will remain disabled.
Press the
F2
key to
reset configuration –
all data will be lost.
-or-
(2) Faulty power cable
connection to the
drive.
-or-
(3) Defective SCSI
cable.
1.
The drives indicated were installed in the
wrong place, so they have been disabled.
Reinstall the drives correctly.
Press the
F1
key to restart the computer with the
drive array disabled.
-or-
Press the
F2
key to use the drives as configured
and lose all the data on them.
2.
Repair the connection and press the
F2
key. If
this message is not eliminated by pressing the
F2
key, run the Array Diagnostics Utility
(ADU).
3.
Contact your Compaq authorized service
provider.
continued