POST Error Messages
F-2
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1714
Slot x drive array –
Redundant ROM
checksum error.
Backup ROM has been activated automatically.
Check the firmware version.
1720
Slot x drive array –
S.M.A.R.T. hard drive
detects imminent
failure: SCSI port x:
SCSI ID y
The indicated drive has reported a S.M.A.R.T.
predictive-failure condition. It may fail at some time
in the near future.
Do not replace the drive unless all other drives
on the array are online.
Back up data before
replacing drive(s).
1721
Slot x drive array –
drive parameter
tracking predicts
imminent failure
The following device(s)
should be replaced
when conditions
permit:
(a list of devices will be
given here).
Do not replace the drive unless all other drives
on the array are online.
Back up data before
replacing drive(s).
M&P predictive failure threshold has been
exceeded. The indicated drive(s) may fail at some
time in the near future.
1723
Slot x drive array – to
improve signal
integrity, internal SCSI
connector should be
removed if external
drives are attached to
the same SCSI port
(followed by further
details).
Follow the remaining instructions in the POST
message.
continued