POST Error Messages
F-12
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1786
Slot x Drive Array
Recovery Needed.
The following SCSI
drive(s) need
Automatic Data
Recovery: SCSI port
(
y
): SCSI ID (
x
)
Press the
F1
key to
continue with recovery
of data to drive(s)
.
Press the
F2
key to
continue without
recovery of data to
drive(s)
.
-or-
Slot x drive array
recovery needed.
Automatic Data
Recovery previously
aborted! The following
SCSI drive(s) need
Automatic Data
Recovery (rebuild):
SCSI port (
y
): SCSI ID
(
x
)
Press the
F1
key to
retry Automatic Data
Recovery to drive
.
Press the
F2
key to
continue without
starting Automatic
Data Recovery.
The message normally appears when a drive is
replaced in a fault-tolerant configuration when the
system is powered down. In this case, press the
F1
key to start the Automatic Data Recovery.
The previously aborted version of the 1786 POST
message will appear if the previous rebuild attempt
was aborted for any reason. Run the Array
Diagnostics Utility (ADU) for more information. If
the replacement drive was failed, try using another
replacement drive. If rebuild was aborted due to a
read error from another physical drive in the array:
1.
Back up all readable data on the array.
2.
Run Diagnostics Surface Analysis.
3.
Restore your data.
continued