POST Error Messages
F-6
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
COMPAQ CONFIDENTIAL
Writer: Amy L. Laffitte File Name: o-appf POST Messages
Codename: Executor Part Number: 266328-001 Last Saved On: 4/18/02 2:47 PM
Table F-1: POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1764
Slot x drive array –
capacity expansion
process is temporarily
disabled (followed by a
cause).
The capacity expansion process has been
temporarily disabled for the reason indicated and
will automatically resume. If the array accelerator
has been removed, you must reinstall it for
capacity expansion to continue.
1765
Slot x drive array
Option ROM appears
to conflict with an ISA
card – ISA cards with
16-bit memory cannot
be configured in
memory range C0000
to DFFFF along with
SMART-2/E 8-bit
Option ROM due to
EISA buffer limitations.
Please remove or
reconfigure your ISA
card.
Remove or reconfigure the conflicting ISA card,
referring to the directions provided with the ISA
card. Alternatively, the Option ROM can be
disabled on the SMART-2/E controller through the
System Configuration Utility if a SMART-2/E is not
the primary (boot) controller.
1766
Slot x drive array
requires System ROM
upgrade.
Run System ROMPaq
Utility.
Run the latest version of the System ROMPaq
utility.
continued