![CommScope FOSC-400A4 Installation Instruction Download Page 9](http://html1.mh-extra.com/html/commscope/fosc-400a4/fosc-400a4_installation-instruction_2643747009.webp)
9
6.7
Shrink down the end of the sleeve on
the cable side. Heat until the sleeve shrinks
down on the cables and take care that the
green thermo-indicating paint is converted to
black. Postheat the clip on both sides till the
adhesive shows a proper flow on the clip
between the two cables.
Wait until the sleeve is cool to the touch
before moving the cables.
6.6
Shrink the oval cable seal on the FOSC-
base side with the recommended hot air gun
device with reflector. Shrink sleeve until the
green thermo-indicating paint is converted to
black. (Make sure the hot-air temperature is at
least 350°C).
(If a FACC-HEAT-GUN-220V is used, set
position on scale 10).
6.4
Match the blue line of the aluminium
cable protection foil with the marks on the
cables. Wrap aluminium cable protection foil
around cable.
6.5
Slide the oval cable seal over the oval
port. Install the branch-off clip. Check that
the heat-shrinkable sleeve butts up against
the FOSC-base and the branch-off clip is
completely inserted. Tape the two cables
together.