![CommScope FOSC-400A4 Installation Instruction Download Page 13](http://html1.mh-extra.com/html/commscope/fosc-400a4/fosc-400a4_installation-instruction_2643747013.webp)
13
8.1
If additional trays are to be used, align
the tray pins with the holes on base bracket.
Squeeze tray pins and slip tray into bracket.
9.1
Lock the two trays together with the tray
wedge.
9.2
Open and remove the desiccant bag
from its package and place the desiccant bag
on the upper tray. Secure the desiccant bag
onto the trays with tape.
9.3
. Ensure seal areas and sealing ring are
clean and sealing ring is in place at the base.
Important.
Make sure the sealing ring is well
positioned.
8.3
Use tray wedge to keep the tray in
upward position.
8.2
Proceed for fiber splicing as described
from point 7. However, provide enough slack
on transportation tube such that no severe
bending or kinking of tube may occur during
hinging.
8
Tray
kit
9
Dome installation