Thoroughly clean oval port and cable
sheath with the cleaning tissue over a
distance of 100 mm from the edge of the
port.
6.2
Abrade oval port and cable sheath
circumferentially on the cleaned area with the
abrasive strip. Remove any abraded material
with a clean cloth.
6.3
Place oval seal over the oval port and
cable. Mark the sleeve length onto the cable.
5.4
Align cable ring cuts with edge of
base.
5.5
Install the screw and washer into the
strength member fixation device. Slide the
cable strength member under the washer and
tighten the screw. Cut the excess length of the
cable strength member.
5.6
If required, connect shield continuity
wire of both cables with shield continuity
clip. Talk pairs, if present, will be connected
together according to the local procedures.