ADCP-96-167 • Issue 5 • July 2016
Page 59
© 2016, CommScope, Inc.
9. Grasp the splitter using thumb and forefinger (see
) and gently squeeze
the locking tab against the lower tab.
Figure 55. Splitter Installation
10. Carefully slide splitter into the mounting slot. Listen for a click to ensure full
engagement.
11. Install the connector packs in the storage panels as described in
.
8.2
Installing The Splitter Connector Packs in the Storage Panel
Use the following procedure to install the connector packs in the storage panel at the
bottom of the cabinet:
1. Following installation of a splitter module, locate an open connector pack slot in
the storage panel at the bottom of the cabinet.
2. Insert the connector pack into the unused slot in the storage panel as shown in
. The storage panel can accommodate four 8-position connector packs
or two 16-position connector packs. Refer to the FDH 3000 Plug and Play Splitter
Caution: Applying excessive force to the splitter during installation can cause splitter
damage. If resistance is encountered when sliding the splitter into the mounting slot,
remove the splitter and verify that the splitter dust cap has been removed and that no
obstructions are present.
REMOVE PROTECTIVE
TAPE AND DUST CAP
BEFORE INSTALLING
SPLITTER
GRIP LOCKING TAB
AND LOWER TAB AS
SHOWN IN DETAIL A
24251-A
SPLITTER
LOCKING
TAB
DETAIL A
LOWER
TAB