APR/16/2002
6979 USA
21
a. Press the
button on the transmitter to stop engine running. You have been completed this
programming successfully.
b. Press
or
button on the transmitter to exit the program mode. There will be 3 long chirps for
confirmation.
3. If the crank time is too long, (Engine already successfully running, while still cranks):
a. Press the '
' button on the transmitter to stop engine running.
Press
button on the transmitter to set proper “Check Level ” to Low position. [2] LED flash,
[2] chirps to confirm this setting
b. Repeat the step1 – 4.
4. If the crank time is too short, (Engine not running, while stops cranks):
a. Press the
button on the transmitter to stop engine running.
Press
button on the transmitter to set proper “ Check Level ” to Hi position. [1] LED flash,
[1] chirp to confirm this setting
b. Repeat the step1 – 4.
VOLTAGE CHECKING TYPE
Enter Start Feature ‘II’
Programming Mode:
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch
10
times and hold it until
five
chirps with a long chirp is hearing then release the
valet switch. You are now in the Start feature
‘II’
programming mode.
Select “Checking Type”:
3. Press the transmitter
button to set the “Voltage Checking Type”. [2] LED flash, [2] chirps to confirm
this setting
4. Once you complete step 3, you can adjust and test “Start Timer” as below:
START TIMER PROGRAMMING: (TEST and ADJUST)
While the system stay in Start Feature
“II”
programming mode,
1. Press the
button on the transmitter to start the vehicle.
2. If everything goes well:
Wait for 10 seconds:
a. If the engine still running.
I. Press the
button on the transmitter to stop engine running. You have been completed this
programming successfully.
II. Press
or
button on the transmitter to exit the program mode. There will be 3 long chirps for
confirmation.
b. If the engine shut down after the vehicle has been started.
I. Press the '
button on the transmitter to stop engine running.
II. Press
button on the transmitter to set “
Check Level
” to LOW position. [2] LED flash,
[2] chirps to confirm this setting
III. Repeat the step1 – 2.
3. If the crank time is too long, (Engine already successfully running, while still cranks):
a. Press the
button on the transmitter to stop engine running.
b. Press
button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm this
enter. (Decrease “Start Timer” is necessary.)
c. Repeat the step1 – 4.
4. If the crank time is too short, (Engine not running, while stops cranks):
a. Press the
button on the transmitter to stop engine running.
b. Press
button on the transmitter to set proper “Start Timer”. The chirp & LED pause will confirm this
enter. (Increase “Start Timer ” is necessary.)
c. Repeat the step1 – 4.
Timer Checking Type
Enter Start Feature ‘II’
Programming Mode:
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.