Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to
confirm exit.
Door Ajar Error Chirp on/off:
This feature controls the error chirp that is generated if the system is armed with the door trigger active. This
useful in vehicles that has a long dome light delay after the door has been closed. If the system is armed
before the dome light has turned off, the security system will generate the door trigger error chirp. If this error
chirp is not desired, use this feature to disable the door open error chirp. If the bypass chirp is turn off, no
bypass chirp will be generated, ever if a door is accidentally left open.
Active Arming With Passive Starter Disables
: The “Ground-when-armed output will go active 60 seconds
after the ignition is turn off. The LED will flash at half its normal rate when the ignition is turn off to indicate
that the system will interrupt the starter in 60 seconds.
Transmitter Can Be Arming The System When Drive
: Press and hold the
button on the transmitter for
2 seconds while the ignition is “ON”. The system will be arm and the system will not respond to any trigger
input except the door triggers and starter disable relay (if installed) will no be activated.
ALARM FEATURE “
II
” PRORAMMING:
1 Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2 Push the Valet switch
4
times and hold it until
two
chirps with a long chirp is hearing then release the
valet switch. You are now in the Alarm feature
‘II’
programming mode.
3 Press and release the transmitter button ‘A’ corresponding to the feature ‘A’ you want to program.
Press
T
ransmitte
r
Button
One Chirp / LED one
pulse
Factory Default
Setting
Two Chirps / LED
two pulse
Three Chirps / LED
three pulse
Four Chirps / LED
four pulse
1
0.8-second Door
lock pulses.
3.5-second Door
lock pulse.
Double pulse unlock
2
Ignition controlled
door locks & unlocks
Ignition controlled
door locks only
Ignition controlled
door unlocks only
Without ignition
controlled door locks
& unlocks
3
H2/4 Brown Wire =
Constant Siren
output for 6-tone
siren
H2/4 Brown Wire =
5-second pulse Siren
output for signal tone
siren
H2/4 Brown Wire =
Random pulse Siren
output
H2/4 Brown Wire =
Horn Output
4
Pathway illumination
feature “off”
Parking light “on” for
30- second upon an
unlock signal
Parking light “on” for
30- second upon an
unlock signal &
10-second upon a
lock signal.
5
With code “hopping”
Without code”
hopping”
6
H9/2 Gray Wire
Channel 2 Output =
1 second pulse
output for trunk
release.
H9/2 Gray Wire
Channel 2 Output =
Momentary output
H9/2 Gray Wire Channel 2 Output = Latched
(3) / Latch output and reset with ignition “on”
(4) / 30-second timer output (5) / 60-second
timer output (6)
Exit
:
Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to
confirm exit.
Momentary output
= The momentary output selection will output a negative signal from the Channel 2
output immediately when the channel 2 button is pressed and will continue until the button is release.
Latched output
= The latched output selection will output a negative signal as soon as the Channel 2 button
is pressed and will continue until the button is pressed again.
Latched output / reset with ignition
= The latched / reset with ignition output selection operates just like
the latched output but will reset or stop when the ignition is turned on.