Turn on AC power to the system. The thermostat will automatically search for and 

identify the digitally communicating components installed.

t

hermoStat

 m

eSSageS

While  searching  for  system  components, 

the  thermostat  will  scroll  the  word 

“SEARCHING”

  in  the  message  area  to 

indicate  that  the  system  is  looking  for 

components  (Air  Handler,  Furnace,  Heat 

Pump,  Air  Conditioner)  on  the  Climate 

Talk  network.  Once  the  components  are 

identified, the message display will indicate 

the  components  found.  Confirmation  will 

be  displayed  in  the  message  area  that 

the  equipment  has  been  found  with  the 

message 

<equipment> FOUND.  

a

uto

-C

onfiguration

The  system  will  auto-configure  itself 

once  all  system  components  have  been 

identified.  The  result  is  that  the  system 

automatically configures all airflows, adjust- 

ments,  and  timings.  However,  the  system 

offers  additional  flexibility  that  allows  for 

the modification of certain auto-configured 

parameters.  See  air  handler/  furnace  and 

AC/heat  pump  instructions  for  additional 

information.

D

iagnoStiCS

Sub-menu Item

Indication/User 

Modifiable Options

Comments

Fault 1 (FAULT #1)

Most recent air handler fault

For display only

Fault 2 (FAULT #2)

Next most recent  

air handler fault

For display only

Fault 3 (FAULT #3)

Next most recent  

air handler fault

For display only

Fault 4 (FAULT #4)

Next most recent  

air handler fault

For display only

Fault 5 (FAULT #5)

Next most recent  

air handler fault

For display only

Fault 6 (FAULT #6)

Least recent air handler fault For display only

Clear Fault History

(CLEAR)

NO or YES

Selecting “YES” clears the fault 

history

Identification

Sub-menu Item

Indication (for Display Only; not User Modifiable)

Model Number  

(MOD NUM)

Displays the air handler model number

Serial Number 

(SER NUM)

Displays the air handler serial number (Optional)

Software 

(SOFTWARE)

Displays application software revision

NOTE:

 Consecutively repeated faults are shown a maximum of 3 times.

If  the  thermostat  continues  to  display 

the word “SEARCHING” after 2-3 minutes, 

this  indicates  that  no  components  were 

found.   Check the components for proper 

connection  of  the  4  wire  network.    If 

after  2-3  minutes,  the  message  “CHECK 

SYSTEM”  appears,  this  indicates  that  an 

outdoor unit was found but not an indoor 

unit.  Check the connection of the indoor 

component. 

Summary of Contents for CTK01

Page 1: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS Installation and Start Up Instructions An Exclusive Touchscreen Control Featuring Serial Communication Model CTK01...

Page 2: ...el applications dehumidification filter maintenance reminders outdoor temperature display and advanced menus The various options and display areas are described below FAILURE TO READ AND FOLLOW ALL IN...

Page 3: ...r Up 9 Power Up 9 Thermostat Messages 9 Auto Configuration 9 Check System Operation 10 Thermostat Set up 11 Set Current Time and Day 11 Choose the System Setting 12 Energy Saving Factory Program 12 Th...

Page 4: ...s communicating control kit contains the following components 1 Communicating touchscreen control with sub base 1 230 VAC to 24 VAC 40 VA transformer B1141643 2 Tyco 284041 4 4 position plug color cod...

Page 5: ...ry tag to prevent power drainage The battery tag must be removed to engage the batteries The batteries are required to maintain time during a power outage They are also required for armchair programmi...

Page 6: ...system requires four wire connections 24VAC Hot R 24VAC Common C Data 1 1 and Data 2 2 The R and C connections provide a 24VAC power supply that can be shared between the indoor and outdoor units and...

Page 7: ...r to the 240VAC COM terminal on the transformer Connect the other end of the wire jumper to L2 on the outdoor unit s control Connect the terminated end of the red 14 wire jumper to the 24VAC terminal...

Page 8: ...stat Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit Place base at installation location and mark mounting hole locations on wall usi...

Page 9: ...hat the equipment has been found with the message equipment FOUND Auto Configuration The system will auto configure itself once all system components have been identified The result is that the system...

Page 10: ...ng Heating System Press Run Schedule Press to adjust thermostat setting above room temperature The heating system should begin to operate Press to adjust thermostat setting below room temperature The...

Page 11: ...isplay Touch either the or key until you reach the correct hour and AM or PM designation Then touch Set Time again to display min utes only in clock display Touch and hold either the or keys until you...

Page 12: ...system Em Emergency setting available only when the thermostat detects a heat pump in the system Auto Auto Changeover is used where both heating and cooling may be required during the same day Auto al...

Page 13: ...cation setting Default is OFF It can be set in the range of 40 to 94 Above 94 is the OFF setting Ideally the indoor humidity should be set in the range of 40 to 60 When On Demand Dehumidification is s...

Page 14: ...nged to 0 Days to indicate no programs will be run When set for 7 Days the thermostat will follow the factory program or the program that you entered Select Energy Management Recovery Scrolling Messag...

Page 15: ...ht will turn on momentarily Select temperature offset Scrolling message will show TEMPERATURE ADJUSTMENT Default is 0 with current temperature Adjustment can be made from 5 Lo to 5 HI to change the di...

Page 16: ...air filter maintenance reminder Scrolling message will show AIR FILTER MAINTENANCE Default is OFF It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of...

Page 17: ...may be required on the same day Auto allows the thermostat to automatically switch between heating and cooling operation Auxiliary Heating When the thermostat is configured for Heat Pump mode and an...

Page 18: ...the screen Touch the Hold key to maintain the new set point temperature Hold At will display to the left of the temperature set point To cancel the permanent hold setting at any time and return to th...

Page 19: ...period The display will show FAN On Prog Check System Status If the Home Screen Display indicates Call for Service and Check Equipment Name inthescrollingmessagearea there is a fault in the system Whe...

Page 20: ...Installer Config key again for approximately 3 seconds to enter the Advanced Installer Configuration menu 1 2 Fault Status The display will change to the Fault Screen indicating any faults that may b...

Page 21: ...to enter that equipment sub menu listing The scrolling message area will show WORKING to indicate that the thermostat is retrieving data Then the first equipment sub menu name appears in the scrolling...

Page 22: ...ange is accepted If the change does not get accepted the display will show FAIL and then change back to the Fault Screen Some of the parameters being displayed on a sub menu are long and switch betwee...

Page 23: ...eparticular piece of equipment It also provides a means to clear the fault history Identification This sub menu item provides access to the model number and serial number optional for the particular p...

Page 24: ...led Temperature HP BAL PNT OFF or 0 to 50 F in 5 F increments Available only for air handler heat pump systems Disables heat pump below the selected temperature Balance Point Temperature df BAL PNT OF...

Page 25: ...horse power Diagnostics Sub menu Item Indication User Modifiable Options Comments Fault 1 FAULT 1 Most recent furnace fault For display only Fault 2 FAULT 2 Next most recent furnace fault For display...

Page 26: ...number Optional Software SOFTWARE Displays application software revision Set up Sub menu Item User Modifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the heating airf...

Page 27: ...tage AC unit Cool Airflow Profile CL PRFL A B C or D Selects the airflow profile for the non communicating 1 stage AC unit Cool ON Delay CL ON 5 10 20 or 30 seconds Selects the indoor blower on delay...

Page 28: ...t most recent air handler fault For display only Fault 5 FAULT 5 Next most recent air handler fault For display only Fault 6 FAULT 6 Least recent air handler fault For display only Clear Fault History...

Page 29: ...odifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the electric heating airflow by the selected amount Status Sub menu Item Indication for Display Only not User Modifi...

Page 30: ...fault For display only Fault 2 FAULT 2 Next most recent AC HP fault For display only Fault 3 FAULT 3 Next most recent AC HP fault For display only Fault 4 FAULT 4 Next most recent AC HP fault For dis...

Page 31: ...em User Modifiable Options Comments applies to AC and HP models Cool Airflow Trim CL TRM 10 to 10 in 2 Increments Selects the airflow trim amount applies to air conditioner only Cool Airflow Profile C...

Page 32: ...Heat OFF Delay HT OFF 30 50 70 or 90 seconds 30 min default Selects the indoor blower off delay applies to heat pump only Defrost Interval DEFROST 30 60 90 or 120 min utes 30 min default Selects the...

Page 33: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS 33 NOTES...

Page 34: ...means is also the installing contractor for the unit The warranty period begins on the date of the original installation Where the product is installed in a newly constructed home the date of the ins...

Page 35: ...as described in the installation and operating manual 6 Replacement parts not supplied or designated by Goodman 7 Damage or repairs required as a result of any improper use maintenance operation or se...

Page 36: ...nication Our continuing commitment to quality products may mean a change in specifications without notice 2009 Goodman Manufacturing Company L P Houston TX For complete information on Goodman warranti...

Reviews: