The Thermostat has options that can be selected and adjusted. These options are in the
Thermostat Options Configuration Menu. To enter the menu from the Home Screen Dis-
play, touch the
Menu
key to display additional key choices.
Touch and hold for 3 seconds the
Installer
Config
key. This displays the first menu
item as shown in the next step. Touch
or to change a menu option. Touch
to advance to the next menu item or
to
return to the previous menu item.
Select On Demand Dehumidification
setting. Default is OFF. It can be set in the
range of 40 to 94%. Above 94% is the OFF
setting. Ideally, the indoor humidity should
be set in the range of 40 to 60%.
When On Demand Dehumidification is
selected On, the thermostat will indicate
the current humidity on the home screen.
The display will show
RH
with the humidity
%. If the current humidity is above the
selected setting, the thermostat will send
an On Demand Dehumidification request.
On Demand Dehumidification improves
the comfort level in your home by reducing
the humidity level. This is accomplished by
slowing down the system fan speed and
lengthening the run time. The humidity
setting may not be reached before the call
for cool has been satisfied as the system
priority is to maintain the temperature in
the home.
1
2
t
hermoStat
u
Ser
m
enuS
S
et
-
uP
Sub-menu Item
User Modifiable Options
Comments
Outdoor
Temperature Display
(od TEMP)
ON = OD Temp is displayed
continuously
bL = Alternates OD temp
and time
OFF = Time is displayed
continuously
Resistance Heat
Disable Temperature
(AUX HT LOCKOUT)
From heat pump disable
temperature to 95˚F in 5˚F
increments
Available only for air h heat
pump systems. Disables electric
resistance heat above the selected
temperature.
Heat Pump Disabled
Temperature
(HP BAL PNT)
OFF or 0 to 50˚F in 5˚F
increments
Available only for air h heat
pump systems. Disables heat pump
below the selected temperature.
Balance Point
Temperature
(df BAL PNT)
OFF or 0 to 50˚F in 5˚F
increments
Available only for f heat
pump systems (dual fuel systems).
Switches from heat pump to fossil
fuel equipment (furnace) below the
selected temperature.
System Test
(TEST SYSTEM)
NO or YES
Starts a system test that steps
the system through the available
system modes of operation.
S
tatuS
Sub-menu Item
Indication (for Display Only; not User Modifiable)
Configuration
(CONFIG)
Displays the actual system configuration (1-stage, 2-stage,
dual fuel, etc.)
Operational Status
(STATUS)
Displays the current operating status for the thermostat