background image

INST
ALLA

TION

POWER UP

SETUP

USAGE GUIDE

ADV
ANCED MENUS

INST

ALLA

TION

POWER UP

SETUP

USAGE GUIDE

ADV

ANCED MENUS

 

3

 

 

 

34

 

 

Table of Contents

Introduction

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inside Front Cover

Installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4

Thermostat Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4

Valid System Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4

Battery Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5

Thermostat Installation Location  . . . . . . . . . . . . . . . . . . . . . . . . . .   6 

Wiring Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   6

Quick Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7 

Installing the Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   8

Initial Power Up

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

 

Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

Thermostat Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

Auto-Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9

Check System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10

Thermostat Set-up

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

 

Set Current Time and Day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11 

Choose the System Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12 

Energy Saving Factory Program  . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

Thermostat Set-up Options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13

Using the Thermostat

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17

 

Advanced Installer Configuration Menu 

. . . . . . . . . . . . . . . . . . . .  20

 

Entering and Navigating the Advanced Installer

    Configuration Menu/Service Information . . . . . . . . . . . . . . . .  20

Equipment User Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  21

Thermostat User Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24

Furnace User Menus  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  25

Air Handler User Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  27

Air Conditioner and Heat Pump User Menus . . . . . . . . . . . . . . .  30

LIMITED WARRANTY

Model CTK01AA

This thermostat (“control”) is warranted by Goodman Manufacturing Company, L.P. (“Goodman”) to 

be free from defects in materials and workmanship under normal use and maintenance, as described 

below:

To the original equipment registered owner and his or her spouse (“owner”) this control is warranted 

for a period of TEN YEARS, except as provided below. This warranty applies only if:

1)  The control is installed in an owner-occupied, single family residence; and

2)  The control is installed in conjunction with a new furnace or air handler containing a communicating 

system that is compatible with the control (a “Compatible Unit”); and

3)  If the Compatible Unit is a Goodman® or Amana® brand furnace or air handler, the owner has 

properly  registered  the  furnace  or  air  handler  with  Goodman  [at  www.goodmanmfg.com]  or 

Amana [at amana-hac.com]; but failure by California and Quebec residents to register a Goodman® 

or Amana® brand Compatible Unit does not diminish their warranty rights.

If the above warranty does not apply, then the control is warranted for a period of 5 YEARS. 

No  warranty  continues  after  the  control  is  removed  from  the  location  where  it  was  originally 

installed.

No warranty applies to, and no warranty is offered by Goodman on, any control ordered over the 

Internet, by telephone or other electronic means unless the dealer selling the unit over the Internet, 

by telephone or other electronic means is also the installing contractor for the unit.

The warranty period begins on the date of the original installation. Where the product is installed in a 

newly constructed home; the date of the installation is the date the homeowner purchased the home 

from the builder. If that date cannot be verified, the warranty period begins three months from the 

month of manufacture (as indicated by the four digit date code (yyww) where “yy” indicates the year 

and “ww” indicates the week of manufacture located on the base plate).

As its only responsibility, and your only remedy, Goodman will, without charge, replace any control 

found  to  be  defective  due  to  workmanship  or  materials  under  normal  use  and  maintenance.  For 

warranty credit, the defective control must be returned to a Goodman heating and air conditioning 

products distributor by a state certified or licensed contractor.

This warranty does not apply to labor, freight, or any other cost associated with the service, repair or 

operation of the unit.

This warranty is in lieu of all other express warranties. ALL IMPLIED WARRANTIES, INCLUDING BUT 

NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, ARE 

LIMITED TO THE DURATION OF THIS WARRANTY. Some states and provinces do not allow limitations 

on how long an implied warranty lasts, so the above limitation may not apply to you.

GOODMAN  SHALL  IN  NO  EVENT  BE  LIABLE  FOR  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES, 

INCLUDING BUT NOT LIMITED TO EXTRA UTILITY EXPENSES OR DAMAGES TO PROPERTY. Some states 

and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the 

above exclusion may not apply to you.

Summary of Contents for CTK01

Page 1: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS Installation and Start Up Instructions An Exclusive Touchscreen Control Featuring Serial Communication Model CTK01...

Page 2: ...el applications dehumidification filter maintenance reminders outdoor temperature display and advanced menus The various options and display areas are described below FAILURE TO READ AND FOLLOW ALL IN...

Page 3: ...r Up 9 Power Up 9 Thermostat Messages 9 Auto Configuration 9 Check System Operation 10 Thermostat Set up 11 Set Current Time and Day 11 Choose the System Setting 12 Energy Saving Factory Program 12 Th...

Page 4: ...s communicating control kit contains the following components 1 Communicating touchscreen control with sub base 1 230 VAC to 24 VAC 40 VA transformer B1141643 2 Tyco 284041 4 4 position plug color cod...

Page 5: ...ry tag to prevent power drainage The battery tag must be removed to engage the batteries The batteries are required to maintain time during a power outage They are also required for armchair programmi...

Page 6: ...system requires four wire connections 24VAC Hot R 24VAC Common C Data 1 1 and Data 2 2 The R and C connections provide a 24VAC power supply that can be shared between the indoor and outdoor units and...

Page 7: ...r to the 240VAC COM terminal on the transformer Connect the other end of the wire jumper to L2 on the outdoor unit s control Connect the terminated end of the red 14 wire jumper to the 24VAC terminal...

Page 8: ...stat Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit Place base at installation location and mark mounting hole locations on wall usi...

Page 9: ...hat the equipment has been found with the message equipment FOUND Auto Configuration The system will auto configure itself once all system components have been identified The result is that the system...

Page 10: ...ng Heating System Press Run Schedule Press to adjust thermostat setting above room temperature The heating system should begin to operate Press to adjust thermostat setting below room temperature The...

Page 11: ...isplay Touch either the or key until you reach the correct hour and AM or PM designation Then touch Set Time again to display min utes only in clock display Touch and hold either the or keys until you...

Page 12: ...system Em Emergency setting available only when the thermostat detects a heat pump in the system Auto Auto Changeover is used where both heating and cooling may be required during the same day Auto al...

Page 13: ...cation setting Default is OFF It can be set in the range of 40 to 94 Above 94 is the OFF setting Ideally the indoor humidity should be set in the range of 40 to 60 When On Demand Dehumidification is s...

Page 14: ...nged to 0 Days to indicate no programs will be run When set for 7 Days the thermostat will follow the factory program or the program that you entered Select Energy Management Recovery Scrolling Messag...

Page 15: ...ht will turn on momentarily Select temperature offset Scrolling message will show TEMPERATURE ADJUSTMENT Default is 0 with current temperature Adjustment can be made from 5 Lo to 5 HI to change the di...

Page 16: ...air filter maintenance reminder Scrolling message will show AIR FILTER MAINTENANCE Default is OFF It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of...

Page 17: ...may be required on the same day Auto allows the thermostat to automatically switch between heating and cooling operation Auxiliary Heating When the thermostat is configured for Heat Pump mode and an...

Page 18: ...the screen Touch the Hold key to maintain the new set point temperature Hold At will display to the left of the temperature set point To cancel the permanent hold setting at any time and return to th...

Page 19: ...period The display will show FAN On Prog Check System Status If the Home Screen Display indicates Call for Service and Check Equipment Name inthescrollingmessagearea there is a fault in the system Whe...

Page 20: ...Installer Config key again for approximately 3 seconds to enter the Advanced Installer Configuration menu 1 2 Fault Status The display will change to the Fault Screen indicating any faults that may b...

Page 21: ...to enter that equipment sub menu listing The scrolling message area will show WORKING to indicate that the thermostat is retrieving data Then the first equipment sub menu name appears in the scrolling...

Page 22: ...ange is accepted If the change does not get accepted the display will show FAIL and then change back to the Fault Screen Some of the parameters being displayed on a sub menu are long and switch betwee...

Page 23: ...eparticular piece of equipment It also provides a means to clear the fault history Identification This sub menu item provides access to the model number and serial number optional for the particular p...

Page 24: ...led Temperature HP BAL PNT OFF or 0 to 50 F in 5 F increments Available only for air handler heat pump systems Disables heat pump below the selected temperature Balance Point Temperature df BAL PNT OF...

Page 25: ...horse power Diagnostics Sub menu Item Indication User Modifiable Options Comments Fault 1 FAULT 1 Most recent furnace fault For display only Fault 2 FAULT 2 Next most recent furnace fault For display...

Page 26: ...number Optional Software SOFTWARE Displays application software revision Set up Sub menu Item User Modifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the heating airf...

Page 27: ...tage AC unit Cool Airflow Profile CL PRFL A B C or D Selects the airflow profile for the non communicating 1 stage AC unit Cool ON Delay CL ON 5 10 20 or 30 seconds Selects the indoor blower on delay...

Page 28: ...t most recent air handler fault For display only Fault 5 FAULT 5 Next most recent air handler fault For display only Fault 6 FAULT 6 Least recent air handler fault For display only Clear Fault History...

Page 29: ...odifiable Options Comments Heat Airflow Trim HT TRM 10 to 10 in 2 Incre ments Trims the electric heating airflow by the selected amount Status Sub menu Item Indication for Display Only not User Modifi...

Page 30: ...fault For display only Fault 2 FAULT 2 Next most recent AC HP fault For display only Fault 3 FAULT 3 Next most recent AC HP fault For display only Fault 4 FAULT 4 Next most recent AC HP fault For dis...

Page 31: ...em User Modifiable Options Comments applies to AC and HP models Cool Airflow Trim CL TRM 10 to 10 in 2 Increments Selects the airflow trim amount applies to air conditioner only Cool Airflow Profile C...

Page 32: ...Heat OFF Delay HT OFF 30 50 70 or 90 seconds 30 min default Selects the indoor blower off delay applies to heat pump only Defrost Interval DEFROST 30 60 90 or 120 min utes 30 min default Selects the...

Page 33: ...INSTALLATION POWER UP SETUP USAGE GUIDE ADVANCED MENUS 33 NOTES...

Page 34: ...means is also the installing contractor for the unit The warranty period begins on the date of the original installation Where the product is installed in a newly constructed home the date of the ins...

Page 35: ...as described in the installation and operating manual 6 Replacement parts not supplied or designated by Goodman 7 Damage or repairs required as a result of any improper use maintenance operation or se...

Page 36: ...nication Our continuing commitment to quality products may mean a change in specifications without notice 2009 Goodman Manufacturing Company L P Houston TX For complete information on Goodman warranti...

Reviews: