INST
ALLA
TION
POWER UP
SETUP
USAGE GUIDE
ADV
ANCED MENUS
INST
ALLA
TION
POWER UP
SETUP
USAGE GUIDE
ADV
ANCED MENUS
10
27
I
nItIal
P
ower
u
P
a
dvanced
I
nstaller
c
onfIguratIon
M
enu
C
heCK
S
yStem
o
Peration
Fan Operation
Turn power on to the system.
Press
Run Schedule
.
Press
FAN
until
FAN On
is displayed. The fan should begin to operate.
Press
FAN
until
FAN Auto
is displayed. The fan should stop operating.
Heating System
Press
Run Schedule
.
Press to adjust thermostat setting above room temperature. The heating system
should begin to operate.
Press
to adjust thermostat setting below room temperature. The heating system
should stop operating.
Cooling System
Press
SYSTEM
key until
Cool
is displayed.
Press
to adjust thermostat setting below room temperature. The cooling system
should begin to operate.
Press to adjust thermostat setting above room temperature. The cooling system
should stop operating.
S
tatuS
Sub-menu Item
Indication (for Display Only; not User Modifiable)
Mode (MODE)
Displays the current furnace operating mode
CFM (CFM)
Displays the airflow for the current operating mode
n
on
-C
omm
(a
PPlieS
only
to
a
CommuniCating
furnaCe
matCheD
With
a
non
-
CommuniCating
aC) (S
ee
V
aliD
S
yStem
C
onfigurationS
)
Sub-menu Item
User Modifiable Options
Comments
Cool Airflow
(CL CFM)
18, 24, 30, 36, 42, 48, or 60 Selects the airflow for the non-
communicating 1-stage AC unit
Cool Airflow Trim
(CL TRM)
-10% to +10% in 2%
Increments
Selects the airflow trim amount
for the non-communicating
1-stage AC unit
Cool Airflow Profile
(CL PRFL)
A, B, C, or D
Selects the airflow profile for the non-
communicating 1-stage AC unit
Cool ON Delay
(CL ON)
5, 10, 20, or 30 seconds
Selects the indoor blower on
delay for the non-communicating
1-stage AC unit
Cool OFF Delay
(CL OFF)
30, 60, 90, or 120 seconds
Selects the indoor blower off
delay for the non-communicating
1-stage AC unit
a
ir
h
anDler
u
Ser
m
enuS
C
onfiguration
Sub-menu Item
Indication (for Display Only; not User Modifiable)
Electric Heat Size (HTR KW)
Displays the size, in kW, of the selected electric heaters*
Motor HP (1/2, 3/4 or 1
MTR HP)
Displays the indoor blower motor horse power
Heat ON Delay (HT ON)
Displays the electric heat indoor blower on delay
Heat OFF Delay (HT OFF)
Displays the electric heat indoor blower off delay
Note: Heater kit selection is done via dipswitches on the air handler control - not via user menu.