Operator’s Manual
HP54 Pellet Stove
~ 12 ~
PREFERRED PELLET VENT TERMINATION CLEARANCE
●
The stove vent must terminate on the outside of the building. Horizontal terminations must extend a minimum
of 12” from the wall. Vertical terminations must protrude a minimum 24” from the roof surface. In addition, all clearances listed
below must be met.
SEE FIGURE 7
●
Must have an approved cap (to prevent water from entering) or a 45° downturn with rodent screen.
●
If the termination is located on a windy side of the house, we suggest using an approved house shield to prevent soot from
building up on the side of the house.
●
A vent must not be located where it will become plugged by snow or other material
Figure
7:
Ve
nt
Termination
A:A Minimum 4
’
clearance below or beside any door or window that opens. (This clearance may be reduced to 18” if
using out-side air). We recommend the door or window be kept closed during operation. Minimum 1’ clearance below
or beside any window that does not open.
B:Minimum 1
’
clearance above any door or window that opens
C: Minimum 2
’
clearance from any adjacent building
D:Minimum 7
’
clearance above any grade when adjacent to public walkways
E:Minimum 2
’
clearance above any grass, plants, or other combustible materials.
F:Minimum 3
’
clearance from any forced air intake of any other appliance
G:Minimum 2
’
clearance below eaves or overhangs
H:Minimum1
’
clearance horizontally from combustible wall
X:Must be a minimum of 2
’
above the
roof
NOTE: Vent may not terminate in covered walkway or breeze- way.