Jumper  opened  and  button  shortly  pressed  –  device  goes  to  Info  mode,  see  chapter  „Info 
mode“

 

Jumper  closed  and  button  pressed  for  longer  than  six  seconds  –  causes  restoring  of 
manufacturer  setting 

of  communication  protocol

,  i.e.  sets  Modbus  RTU  communication 

protocol, device address sets to 01h and communication speed to 9600Bd - after button press 
there  is  “dEF”  message  blinking  at  LCD  display.  Six  seconds  later  message  “dEF”  stays 
shown, it means manufacturer setting 

of communication protocol

 is done. 

 

Modbus registers of the device 

Variable 

Unit 

Address[hex]

X

  Address[dec]

X

  Format 

Size 

Status 

Measured 
temperature 

[°C] 

[°F]* 

0x0031 

49 

Int*10 

BIN16 

Address of device 

[-] 

0x2001 

8193 

Int 

BIN16  R/W* 

Code of 
communication 
speed 

[-] 

0x2002 

8194 

Int 

BIN16  R/W* 

Serial number of 
device Hi 

[-] 

0x1035 

4149 

BCD 

BIN16 

Serial number of 
device Lo 

[-] 

0x1036 

4150 

BCD 

BIN16 

Version of 
Firmware Hi 

[-] 

0x3001 

12289 

BCD 

BIN16 

Version of 
Firmware Lo 

[-] 

0x3002 

12290 

BCD 

BIN16 

 

Addition for device T5410 - with atmospheric pressure measurement 

Variable 

Unit* 

Address[hex]

X

  Address[dec]

X

  Format 

Size 

Status 

Atmospheric 

pressure 

hPa  

0x0034 

52 

Int*10 

BIN16 

PSI  

Int*1000 

inHg 

Int*100 

mBar 

Int*10 

oz/in

2

 

Int*10 

mmHg 

Int*10 

inH

2

Int*10 

kPa  

Int*100 

Explanation: 

 

*  

depends on device setting (by User’s software) 

 

Int*10 register is in format integer*10 

 

register is designed only for reading 

 

W* 

register  is  designed  for  writing,  for  details  see  file  “

Description  of  communication 

protocols of Txxxx series

” 

 

X

 

register  addresses  are  indexed  from  zero  –  register  0x31  is  physically  sent  as  value 

0x30, 0x32 as 0x31 (zero based addressing). 

 

Note:

 In case there is a need for reading of measured values from the device with higher resolution 

than one decimal, measured values in device are stored also in „Float“ format, which is not directly 
compatible with IEEE754. 
 

Summary of Contents for T0310

Page 1: ...nd improvement of their products Manufacturer reserves the right to make technical changes to the device without previous notice Misprints reserved Manufacturer is not responsible for damages caused b...

Page 2: ...ware TSensor for setting of all device parameters recommended It is free to download at www cometsystem com It supports make the adjustment of the device too This procedure is described at file Calibr...

Page 3: ...nection to RS232 interface For devices with RS485 output there is recommended to use shielded twisted copper cable maximal length 1200m The cable must be located at indoor rooms Nominal cable impedanc...

Page 4: ...4 IE SNC T03 4 10 T5410 06 Dimensions T0410 T5410 Transmitter with RS485 Dimensions T0310L T0410L T5410L Connection see Appendix B...

Page 5: ...IE SNC T03 4 10 T5410 06 5 Typical application wiring connection of terminals T0310 power from communication port T0310 power from external voltage source T0410 T5410 RS485...

Page 6: ...tocols including examples of communication is available in individual document Description of communication protocols of Txxxx series which is free to download at www cometsystem com Note After switch...

Page 7: ...R Serial number of device Lo 0x1036 4150 BCD BIN16 R Version of Firmware Hi 0x3001 12289 BCD BIN16 R Version of Firmware Lo 0x3002 12290 BCD BIN16 R Addition for device T5410 with atmospheric pressure...

Page 8: ...pressed for longer than six seconds causes restoring of manufacturer setting of communication protocol i e sets Modbus RTU communication protocol device address sets to 01h and communication speed to...

Page 9: ...it of allowed full scale range There is a reading Err1 on LCD display Value read from the device is 999 9 for pressure reading there is 999 9 hPa correct value This state occurs if measured temperatur...

Page 10: ...ameters Ambient temperature RTD sensor Pt1000 3850ppm Measuring range 30 to 80 C Resolution of display 0 1 C Accuracy 0 4 C Atmospheric pressure T5410 only Unit hPa mBar PSI mmHg inHg inH2O oz in2 kPa...

Page 11: ...ions other than specified in technical parameters Devices are not designed for locations with chemically aggressive environment Temperature sensor must not be exposed to direct contact with water or o...

Page 12: ...the corresponding pins of CANON connector for more information see the operation manual for ELO E214 The ELO E06D converter is an optional accessory for connection of transmitter with RS485 interface...

Reviews: