7596004CM - Manuale EASYBLUE COMENDA ENG ok
- 14 -
4 OPERATING
4.1 FIRST START UP
ATTENTION
The first start up of the system must be carried out by the installer who will make sure
the machine runs properly.
Insert the feed plug in a 230V 50Hz power socket equipped with efficient grounding. Now
the system is able to work. It advisable to run the run for at least a half an hour before
drinking it, in order to allow the system to eliminate the substances used to conserve the
reverse osmosis membrane.
Make sure there are no leaks in the circuit and fasten the antiflooding probe on the
bottom of the machine.
Close the cover with the screws position the machine in its final destination and push the
brakes of the whells.
Operate sanitation of equipment as described in section 5.7.
4.2 NORMAL USE
In order to normally use EASY:BLUE the machine must always be kept on.
The machine starts automatically at every rising cycle of the dish/wash machine. Every six hours the
machine automatically opens the inlet solenoid valve, in this way the membranes are washed for 2
minutes. To adjust the salinity of the water, acting on the valve for mixing later.
WARNING
Avoid absolutely membrane dehydration, because this would irreparably compromise the
operation.
The equipment does not require continuous monitoring, but check every day the
conductivity and the remaining hours to filter changing (see § 5.9).
WARNING
At the end of the day, close the inlet water valve and disconnect the power plug.
4.3 BEHAVIOUR IN THE EVENT OF FAILURE
WARNING
In the event of water leak, disconnect the power plug and close the inlet water valve,
then contact the service centre.