Atena Easy Addressable Fire Alarm Panel – Installation and Programming Manual
3
7.3.2 Saving the New Found Devices ................................................................................................... 30
7.3.3 Deleting Devices ........................................................................................................................... 30
7.3.4 Disabling Devices ......................................................................................................................... 30
7.3.5 Fixing of Wrong Type Devices ...................................................................................................... 31
7.3.6 Programming of Device Parameters ............................................................................................ 31
7.5.1 Sounders Outputs ......................................................................................................................... 42
7.5.2 Extinguishing Output..................................................................................................................... 42
7.5.3 Fire Output .................................................................................................................................... 42
7.5.4 Fault Output .................................................................................................................................. 43
7.5.5 Relay Outputs ............................................................................................................................... 43
7.6.1 Access Codes ............................................................................................................................... 44
7.6.2 Setting the Date and Time ............................................................................................................ 45
7.6.3 Setting Day/ Night Alarm Modes .................................................................................................. 45
7.6.4 Panel General Settings ................................................................................................................. 46
7.6.5 Delay
7.6.6 Sounders Mode ............................................................................................................................ 46
7.6.7 Company Logo ............................................................................................................................. 47
7.10.1 Network Settings ......................................................................................................................... 48
7.10.2 Panels Settings ........................................................................................................................... 49
DoP No: 002
Comelit Group S.p.A.
Via Don Arrigoni 5 - 24020 Rovetta S. Lorenzo BG Italy tel. +39 0346 750 011 - fax +39 0346 71436 email:
EN 54-2:1997/A1:2006/AC:1999; EN 54-4:1997/A2:2006/AC:1999
41CPE012EN
Intended for use in fire detection and fire alarm systems in and around buildings.
Essential Characteristics
Performance
Performance under fire conditions
Pass
Response delay (response time to fire)
Pass
Operational reliability
Pass
Durability of operational reliability and response delay: temperature resistance
Pass
Durability of operational reliability: humidity resistance
Pass
Durability of operational reliability: vibration resistance
Pass
Durability of operational reliability: electrical resistance
Pass