  Warning:  The  night  cover  requires  a  careful  handling.  The  night  cover  should  be  raised/lowered 

smoothly, without any jerks and distortions, using a special handle, until the cover fixation. This is necessary to 
avoid damage to the mechanism and wear of the night cover material.  

Warning:  If the customers do not fulfil the above requirements, the warranty for the night cover is not 

provided! 
 
See Appendix E for the night cover installation instructions. 
 

2 Datasheet specifications 

2.1 Scope of delivery 

The delivery set complies with the Packing list (appended to the Manual). 
 

2.2 Acceptance certificate 

Refrigerated  wall  display  case  series  Monte  ____________________,  serial  number  _______________  
is manufactured and accepted in accordance with the requirements of Specification TU 28.25.13-002-066486978 
-2017, current technical documentation and is found fit for use. 
 
Date of manufacture________________201___ 
 
Responsible for the acceptance________________________(signature) 
 
L.S. 
 

3 Proper use 

3.1 General guidelines 

The  Manual  provides  information  necessary  for  the  proper  operation  and  maintenance  of  the  display  cases 
during their intended use. The display case  service life and safety in operation depend on observance of the 
operating rules. 
 

3.2 Safety measures 

The display cases meet the safety requirements of Technical Regulations of the Customs Union: TR CU 004/2011 
"On  safety  of  low-voltage  equipment",  TR  CU  010/2011  "On  safety  of  machinery  and  equipment",  TR  CU 
020/2011 "Electromagnetic compatibility of technical means".  
The display cases belong to I class of human protection against electric shock according to GOST IEC 60335-1. 
The degree of protection provided by enclosures is IP20. 
 

 Warning: Observe the following safety rules when working with the display cases: 

-

 

check the cable before connecting the display cases to the mains and make sure it is working properly; 

-

 

connect the mains plug to a grounded socket only; 

-

 

the power cord may only be replaced by the qualified personnel authorized to this type of works; 

-

 

in  case  of  any  faults  in  the  electrics  (wire  insulation  fault,  ground  wire  breakage,  etc.),  immediately 
disconnect the display case from the mains and call an electrician. 

-

 

connect  the  showcases  to  the  supply  mains  (Fig.4)  via  an  automatic  circuit  breaker  of  combined 
(thermal and electromagnetic) protection with a rated current value of: 

 

   

a)

 

6.3A - for Monte 1250, Monte 1875, Monte 2500; 

b)

 

10А - for Monte 3750. 

 

Summary of Contents for 7469.0100

Page 1: ...Wall Mounted Unit Max 7469 0100 7469 0105 7469 0110 User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi...

Page 2: ...fications 7 2 1 Scope of delivery 7 2 2 Acceptance certificate 7 3 Proper use 7 3 1 General guidelines 7 3 2 Safety measures 7 3 3 Display case installation 8 3 4 Pre starting procedure of display cas...

Page 3: ...maximum relative humidity 80 22 C maximum relative humidity 65 25 C maximum relative humidity 60 The temperature range in the useful volume for the display cases without front glazing open is 1 to 7...

Page 4: ...1 7 0 66 0 27 1955 1075 2040 510 nte L 2500 8 0 4 0 3 25 3 5 2 2 0 86 0 34 2580 1075 2040 610 nte L 3750 12 0 6 0 4 9 5 0 3 1 1 27 0 48 3830 1075 2040 900 nte L FV 1250 3 3 2 0 1 65 1 9 1 2 0 45 0 19...

Page 5: ...g 2 Rear moulded wall 3 Upper moulded wall top 4 Side moulded or double glazed wall end wall 5 Height adjustable support feet 6 Load bearing posts with perforated panels 7 Shelves with guides and stop...

Page 6: ...rosting time and frequency are determined by the controller settings The control panel consists of 1 Electronic controller 2 Illuminated key switch Figure 3 Control panel The electronic controller 1 i...

Page 7: ...of the display cases during their intended use The display case service life and safety in operation depend on observance of the operating rules 3 2 Safety measures The display cases meet the safety...

Page 8: ...ry package Remove the display case from the wooden pallet by unscrewing the fixing bolts Indoors the product can only be moved in accordance with the handling circuit on the nameplate Tilt the display...

Page 9: ...ly after the set temperature is reached in the display case interior DO NOT exceed the load limits Warning Products and semi finished products should be pre cooled Products and semi finished products...

Page 10: ...not installed correctly The refrigeration unit pipelines are in contact with the housing or with each other Adjust the display case installation level using the feet Check the pipeline attachment War...

Page 11: ...e Centers 5 Storage The display cases should be stored factory packaged not stacked under the conditions of exposure to climatic factors of group 3 acc to GOST 15150 and a temperature of not lower tha...

Page 12: ...personal protective equipment Shut down the display cases and disconnect the electrical lines before disposal The process liquid oil refrigerant should be removed from the refrigeration system and re...

Page 13: ...___________________________________________________________________ name of organization ___________________________________________________________________ full name certificate for installation and...

Page 14: ...lights MVE1 MVE6 Air cooler fans A1 Controller ES Evaporator heating elements Sair S5 NTC temperature sensors YA Timer relay coil Option Display case length mm Number of fans Number of lamps Number o...

Page 15: ...15 www combisteel com Appendix C normative Refrigerating unit and melt water drain pipeline connection diagram...

Page 16: ...16 www combisteel com...

Page 17: ...the compressor according to a signal received from the sensor installed in the air cooler If the interior temperature exceeds the set value the first line in Table 1 then the controller activates the...

Page 18: ...unit F F r09 Correction of the signal from thermostat sensor 10 10 0 K r12 Manual service 1 stop regulation 0 start regulation 1 1 r13 Displacement of reference during night operation 10 10 0 K r39 Ac...

Page 19: ...ed sensor type t ntc 5 kOhm ntc 15 Display step 0 5 normal 0 1 at Pt sensor no yes no 16 Maximum hold time after coordinated defrost 20 o46 Cleaning 0 o64 Access code 2 partly access 0 100 0 67 Replac...

Page 20: ...20 www combisteel com Appendix E Night cover installation instructions Step 1 Step 2 Step 3...

Page 21: ...21 www combisteel com Step 4 Step 5...

Reviews: