Introduction 

Thank you for purchasing the Combisteel refrigerated display case. 
This Operating Manual (hereinafter referred to as the "Manual") describes design of the refrigerated wall display 
case  series  Monte  (hereinafter  referred  to  as  the  "Display  Case"  or  the  "Product")  and  its  installation  and 
operation procedures. The display cases should be installed, put into operation and maintained by the Service 
Centers of Combisteel commercial refrigerating equipment suppliers or sellers or other maintenance companies 
on behalf of Combisteel. 
The  display  cases  meet  the  requirements  of  TR  CU  004/2011  "On  safety  of  low-voltage  equipment",  TR  CU 
010/2011 "On safety of machinery and equipment", TR CU 020/2011 "Electromagnetic compatibility of technical 
means" (Declaration of conformity EEU No. RU Д-RU.РА01.В.03335/19, valid until 23.12.2024, and EEU No. RU 
Д-RU.РА01.В.03336/19, valid until 23.12.2023) 
 
Warning: Please read this Manual carefully before putting the display cases into operation. 
 

1 Description and operation 

1.1 Purpose of display cases 

 The display cases are designed for demonstration, sale and temporary storage of pre-cooled food products and 
semi-finished  products  at  trade  and  public  catering  enterprises.  The  display  cases  can  work  with  a  remote 
refrigerating unit or a centralized cold supply. The climate class of the display cases is "N", placement category 3 
according to GOST 15150 for operation at ambient temperature of 12°C to 25°C and relative humidity:   
- 12°C - maximum relative humidity 80%;   

 

 

 

 

 

- 22°C - maximum relative humidity 65 %;   

 

 

 

 

 

- 25°C - maximum relative humidity 60%.   

 

The temperature range in the useful volume for the display cases without front glazing (open) is +1 to +7°C. 
The temperature range in the useful volume for the display cases with front glazing is -1 to +7°C. 
 

1.2 Specifications 

Main specifications of the display cases are given in Table 1 and Fig. 2. 
 

 

Table 1 - Basic parameters and specifications 

 
 

Designation 

of display cases 

Useful 

area, 

sq.m 

 

Useful 

refrigerated 

volume,

 

cub.m 

Cold 

consumption, 

kW 

Energy 

consumption 

per day, not 

more than, 

kW/h/kW/h* 

Input 

current, 

not more 

than A/A* 

External 

dimensions, 
mm: LxWxH  

(including end 

walls) 

Weight, 

kg 

Series Monte S 

Моnte S 1250 

2.7 

1.0 

1.5 

1.9/1.2* 

0.45/0.19* 

1310х775х2040 

290 

Моnte S1875 

4.1 

1.5 

2.2 

2.7/1.7* 

0.66/0.27* 

1955х775х2040 

320 

Моnte S 2500 

5.4 

2.0 

3.0 

3.5/2.2* 

0.86/0.34* 

2580х775х2040 

400 

Моnte S 3750 

8.2 

3.0 

4.4 

5.0/3.1* 

1.27/0.48* 

3830х775х2040 

600 

Моnte S FV 1250  

2.2 

1.0 

1.5 

1.9/1.2* 

0.45/0.19* 

1310х775х2040 

290 

Моnte S FV 1875  

3.4 

1.5 

2.2 

2.7/1.7* 

0.66/0.27* 

1955х775х2040 

320 

Моnte S FV 2500  

4.4 

2.0 

3.0 

3.5/2.2* 

0.86/0.34* 

2580х775х2040 

400 

Моnte S FV 3750  

6.7 

3.0 

4.4 

5.0/3.1* 

1.27/0.48* 

3830х775х2040 

600 

Моnte SH 1250 

3.2 

1.1 

1.5 

1.9/1.2* 

0.45/0.19* 

1310х775х2210 

300 

Моnte SH 1875 

4.7 

1.7 

2.2 

2.7/1.7* 

0.66/0.27* 

1955х775х2210 

350 

Моnte SH 2500 

6.4 

2.2 

3.0 

3.5/2.2* 

0.86/0.34* 

2580х775х2210 

430 

Моnte SH 3750 

9.5 

3.3 

4.4 

5.0/3.1* 

1.27/0.48* 

3830х775х2210 

640 

Моnte SH FV 1250  

2.7 

1.1 

1.5 

1.9/1.2* 

0.45/0.19* 

1310х775х2210 

300 

Моnte SH FV 1875  

4.1 

1.7 

2.2 

2.7/1.7* 

0.66/0.27* 

1955х775х2210 

350 

Моnte SH FV 2500  

5.4 

2.2 

3.0 

3.5/2.2* 

0.86/0.34* 

2580х775х2210 

430 

Моnte SH FV 3750  

8.2 

3.3 

4.4 

5.0/3.1* 

1.27/0.48* 

3830х775х2210 

640 

Summary of Contents for 7469.0100

Page 1: ...Wall Mounted Unit Max 7469 0100 7469 0105 7469 0110 User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi...

Page 2: ...fications 7 2 1 Scope of delivery 7 2 2 Acceptance certificate 7 3 Proper use 7 3 1 General guidelines 7 3 2 Safety measures 7 3 3 Display case installation 8 3 4 Pre starting procedure of display cas...

Page 3: ...maximum relative humidity 80 22 C maximum relative humidity 65 25 C maximum relative humidity 60 The temperature range in the useful volume for the display cases without front glazing open is 1 to 7...

Page 4: ...1 7 0 66 0 27 1955 1075 2040 510 nte L 2500 8 0 4 0 3 25 3 5 2 2 0 86 0 34 2580 1075 2040 610 nte L 3750 12 0 6 0 4 9 5 0 3 1 1 27 0 48 3830 1075 2040 900 nte L FV 1250 3 3 2 0 1 65 1 9 1 2 0 45 0 19...

Page 5: ...g 2 Rear moulded wall 3 Upper moulded wall top 4 Side moulded or double glazed wall end wall 5 Height adjustable support feet 6 Load bearing posts with perforated panels 7 Shelves with guides and stop...

Page 6: ...rosting time and frequency are determined by the controller settings The control panel consists of 1 Electronic controller 2 Illuminated key switch Figure 3 Control panel The electronic controller 1 i...

Page 7: ...of the display cases during their intended use The display case service life and safety in operation depend on observance of the operating rules 3 2 Safety measures The display cases meet the safety...

Page 8: ...ry package Remove the display case from the wooden pallet by unscrewing the fixing bolts Indoors the product can only be moved in accordance with the handling circuit on the nameplate Tilt the display...

Page 9: ...ly after the set temperature is reached in the display case interior DO NOT exceed the load limits Warning Products and semi finished products should be pre cooled Products and semi finished products...

Page 10: ...not installed correctly The refrigeration unit pipelines are in contact with the housing or with each other Adjust the display case installation level using the feet Check the pipeline attachment War...

Page 11: ...e Centers 5 Storage The display cases should be stored factory packaged not stacked under the conditions of exposure to climatic factors of group 3 acc to GOST 15150 and a temperature of not lower tha...

Page 12: ...personal protective equipment Shut down the display cases and disconnect the electrical lines before disposal The process liquid oil refrigerant should be removed from the refrigeration system and re...

Page 13: ...___________________________________________________________________ name of organization ___________________________________________________________________ full name certificate for installation and...

Page 14: ...lights MVE1 MVE6 Air cooler fans A1 Controller ES Evaporator heating elements Sair S5 NTC temperature sensors YA Timer relay coil Option Display case length mm Number of fans Number of lamps Number o...

Page 15: ...15 www combisteel com Appendix C normative Refrigerating unit and melt water drain pipeline connection diagram...

Page 16: ...16 www combisteel com...

Page 17: ...the compressor according to a signal received from the sensor installed in the air cooler If the interior temperature exceeds the set value the first line in Table 1 then the controller activates the...

Page 18: ...unit F F r09 Correction of the signal from thermostat sensor 10 10 0 K r12 Manual service 1 stop regulation 0 start regulation 1 1 r13 Displacement of reference during night operation 10 10 0 K r39 Ac...

Page 19: ...ed sensor type t ntc 5 kOhm ntc 15 Display step 0 5 normal 0 1 at Pt sensor no yes no 16 Maximum hold time after coordinated defrost 20 o46 Cleaning 0 o64 Access code 2 partly access 0 100 0 67 Replac...

Page 20: ...20 www combisteel com Appendix E Night cover installation instructions Step 1 Step 2 Step 3...

Page 21: ...21 www combisteel com Step 4 Step 5...