Series Monte M 

Моnte M 1250 

3.4 

1.4 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х975х2040 

360 

Моnte M 1875 

5.1 

2.1 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2040 

430 

Моnte M 2500 

6.8 

2.8 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х975х2040 

510 

Моnte M 3750 

10.2 

4.2 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х975х2040 

740 

Моnte M FV 1250  

2.8 

1.2 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х975х2040 

360 

Моnte M FV 1875  

4.2 

1.8 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2040 

430 

Моnte M FV 2500  

5.6 

2.4 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х975х2040 

510 

Моnte M FV 3750  

8.3 

3.6 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х975х2040 

740 

Моnte M TG 

5.1 

2.1 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2040 

430 

Моnte M FV TG 

4.2 

1.8 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2040 

430 

Моnte MH 1250 

4.0 

1.5 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х975х2210 

380 

Моnte MH 1875 

6.0 

2.3 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2210 

450 

Моnte MH 2500 

8.1 

3.0 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х975х2210 

530 

Моnte MH 3750 

12.0 

4.6 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х975х2210 

760 

Моnte MH FV 1250  

4.0 

1.3 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х975х2210 

380 

Моnte MH FV 1875  

6.0 

2.0 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2210 

450 

Моnte MH FV 2500  

8.1 

2.6 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х975х2210 

530 

Моnte MH FV 3750  

12.0 

4.0 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х975х2210 

760 

Моnte MH TG 

6.0 

2.3 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2210 

450 

Моnte MH FV TG 

5.9 

2.0 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х975х2210 

450 

Series Monte L 

Моnte L 1250 

4.0 

2.0 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х1075х2040 

430 

Моnte L 1875 

6.0 

3.1 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х1075х2040 

510 

Моnte L 2500 

8.0 

4.0 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х1075х2040 

610 

Моnte L 3750 

12.0 

6.0 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х1075х2040 

900 

Моnte L FV 1250  

3.3 

2.0 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х1075х2040 

430 

Моnte L FV 1875  

4.9 

3.1 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х1075х2040 

510 

Моnte L FV 2500  

6.5 

4.0 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х1075х2040 

610 

Моnte L FV 3750  

9.9 

6.0 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х1075х2040 

900 

Моnte L TG 

6.5 

4.0 

3.25 

3.5/2.2* 

0.86/0.27* 

2580х1075х2040 

610 

Моnte L FV TG 

6.0 

4.0 

3.25 

3.5/2.2* 

0.86/0.27* 

2580х1075х2040 

610 

Моnte LH 1250 

4.8 

2.2 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х1075х2210 

450 

Моnte LH 1875 

6.9 

3.4 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х1075х2210 

550 

Моnte LH 2500 

9.6 

4.4 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х1075х2210 

700 

Моnte LH 3750 

14.4 

6.6 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х1075х2210 

990 

Моnte LH FV 1250  

4.0 

2.2 

1.65 

1.9/1.2* 

0.45/0.19* 

1310х1075х2210 

450 

Моnte LH FV 1875  

6.0 

3.0 

2.5 

2.7/1.7* 

0.66/0.27* 

1955х1075х2210 

550 

Моnte LH FV 2500  

8.0 

4.4 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х1075х2210 

700 

Моnte LH FV 3750  

12.0 

6.6 

4.9 

5.0/3.1* 

1.27/0.48* 

3830х1075х2210 

990 

Моnte LH TG 

8.0 

4.4 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х1075х2210 

700 

Моnte LH FV TG 

6.5 

4.4 

3.25 

3.5/2.2* 

0.86/0.34* 

2580х1075х2210 

700 

 
Note - * - The energy consumption and power parameters when energy-saving fans are used. 
The shelf load should not exceed 120 kg/m² for a five-row display case, and 100 kg/m² for a six-row display. 
 
 
The power supply parameters are as follows: V/phase/ Hz - 230/1/50. The display cases shall remain functional 
at supply voltage deviations in the range of minus 10% to plus 10% from the  rated voltage according to GOST 
13109.  
 
 

 

Summary of Contents for 7469.0100

Page 1: ...Wall Mounted Unit Max 7469 0100 7469 0105 7469 0110 User Manual Gebruikershandleiding Gebrauchsanweisung Le mode d emploi...

Page 2: ...fications 7 2 1 Scope of delivery 7 2 2 Acceptance certificate 7 3 Proper use 7 3 1 General guidelines 7 3 2 Safety measures 7 3 3 Display case installation 8 3 4 Pre starting procedure of display cas...

Page 3: ...maximum relative humidity 80 22 C maximum relative humidity 65 25 C maximum relative humidity 60 The temperature range in the useful volume for the display cases without front glazing open is 1 to 7...

Page 4: ...1 7 0 66 0 27 1955 1075 2040 510 nte L 2500 8 0 4 0 3 25 3 5 2 2 0 86 0 34 2580 1075 2040 610 nte L 3750 12 0 6 0 4 9 5 0 3 1 1 27 0 48 3830 1075 2040 900 nte L FV 1250 3 3 2 0 1 65 1 9 1 2 0 45 0 19...

Page 5: ...g 2 Rear moulded wall 3 Upper moulded wall top 4 Side moulded or double glazed wall end wall 5 Height adjustable support feet 6 Load bearing posts with perforated panels 7 Shelves with guides and stop...

Page 6: ...rosting time and frequency are determined by the controller settings The control panel consists of 1 Electronic controller 2 Illuminated key switch Figure 3 Control panel The electronic controller 1 i...

Page 7: ...of the display cases during their intended use The display case service life and safety in operation depend on observance of the operating rules 3 2 Safety measures The display cases meet the safety...

Page 8: ...ry package Remove the display case from the wooden pallet by unscrewing the fixing bolts Indoors the product can only be moved in accordance with the handling circuit on the nameplate Tilt the display...

Page 9: ...ly after the set temperature is reached in the display case interior DO NOT exceed the load limits Warning Products and semi finished products should be pre cooled Products and semi finished products...

Page 10: ...not installed correctly The refrigeration unit pipelines are in contact with the housing or with each other Adjust the display case installation level using the feet Check the pipeline attachment War...

Page 11: ...e Centers 5 Storage The display cases should be stored factory packaged not stacked under the conditions of exposure to climatic factors of group 3 acc to GOST 15150 and a temperature of not lower tha...

Page 12: ...personal protective equipment Shut down the display cases and disconnect the electrical lines before disposal The process liquid oil refrigerant should be removed from the refrigeration system and re...

Page 13: ...___________________________________________________________________ name of organization ___________________________________________________________________ full name certificate for installation and...

Page 14: ...lights MVE1 MVE6 Air cooler fans A1 Controller ES Evaporator heating elements Sair S5 NTC temperature sensors YA Timer relay coil Option Display case length mm Number of fans Number of lamps Number o...

Page 15: ...15 www combisteel com Appendix C normative Refrigerating unit and melt water drain pipeline connection diagram...

Page 16: ...16 www combisteel com...

Page 17: ...the compressor according to a signal received from the sensor installed in the air cooler If the interior temperature exceeds the set value the first line in Table 1 then the controller activates the...

Page 18: ...unit F F r09 Correction of the signal from thermostat sensor 10 10 0 K r12 Manual service 1 stop regulation 0 start regulation 1 1 r13 Displacement of reference during night operation 10 10 0 K r39 Ac...

Page 19: ...ed sensor type t ntc 5 kOhm ntc 15 Display step 0 5 normal 0 1 at Pt sensor no yes no 16 Maximum hold time after coordinated defrost 20 o46 Cleaning 0 o64 Access code 2 partly access 0 100 0 67 Replac...

Page 20: ...20 www combisteel com Appendix E Night cover installation instructions Step 1 Step 2 Step 3...

Page 21: ...21 www combisteel com Step 4 Step 5...

Reviews: