The manufacturer provides all pneumatic lines on the blender piped to a single ¼” NPT
standard pipe thread fitting. The Slide Gate/Auger blending system requires approximately 1
cfm (1.7 m³/hr) @ 60 psi (4.14 bar) maximum air pressure for proper operation.
The working pressure of the blender cylinders is not to exceed 60 psi (4.14 bar). This is
adjustable by the regulator supplied on the rear panel of the blender. It is important to prevent
fluctuation in the air pressure to the blender by not installing the unit on an airline. If this is
the case, an accumulator tank with a check valve may have to be provided by the customer to
ensure the blender a steady air supply.
Caution!
To prevent damage to the equipment, do not exceed 60 psi (4.14 bar) air
pressure.
Caution!
Always disconnect the compressed air supply when working on any part of
the blender.
3-5 Initial Set-up
This section will discuss the mechanical setup and control system setup of the Slide Gate
blending system. After reading this section, you should be familiar with the mechanical setup
and the electronic control setup of the blending system.
Mechanical Set-up
Stroke Limiters for Metering Gates
Stroke limiters are supplied on components 1 through 6 with all Slide Gate blenders to allow
standard metering gates to meter small amounts of low percentage additive materials.
Generally, the stroke limiter is not required on major ingredients (usually number 1 and 3)
and should be adjusted to the rear-most position. If they are used on components number 1
and 3 the throughput of the blender will be reduced.
To install the stroke limiter, drop it into the double slot on top of the gate assembly and
secure it in place with the button head screw that is provided. Be sure to use the lock washer
to prevent the stroke limiter from coming loose.
Figure 24: Stroke Limiters
BF1-615.3
Chapter 3: 2BInstallation
35 of 101
Summary of Contents for 882.00273.00
Page 22: ...Figure 11 Typical Operator Screens BF1 615 3 Chapter 2 1BFunctional Description 22 of 101...
Page 23: ...Figure 12 Typical Setup Screens BF1 615 3 Chapter 2 1BFunctional Description 23 of 101...
Page 24: ...BF1 615 3 Chapter 2 1BFunctional Description 24 of 101...