26
Chapter 4
D
Note
Keeping the mains connected
irreversibly damages the product.
4.2.4 Replace an RGB Light Engine
The RGB Light Engine position in Luminous Textile: starts with Out 1
connected to RGB Light Engine at bottom as shown.
Figure 29, RGB Light Engine position in Luminous Textile.
1 Remove the Luminous Textile from the wall or ceiling and disconnect the
mains and ethernet cable (see
Installation Guide
).
2 Place the Luminous Textile on a clean surface.
3 Locate the defective module by plugging in the mains cable.
4 Disconnect the mains cable again!
5 Find the serial numbers of the Luminous Textile as described in section
and contact the local Signify representative for an RMA
form.
6 Remove the bus cover with a 3 mm Allen key.
Figure 30, Remove the bus cover
module 1
module 2
3 mm
bus cover
2
1
3 ×