23
“Push to Select” button on the front touch pad (#571.2)
until the beater mode is selected. Allow the machine to
run in the beater mode for approximately 10 seconds
then push the “Stop” button on the touch pad. This
will remove any of the remaining sanitizer from the
cylinder.
After the sanitizer has completely drained, close the
dispensing handle.
!! IMPORTANT !!
The freezer is now sanitized and ready to be filled
with fresh liquid mix. Do not wipe out any residual
sanitizing solution from the bottom of the mix
storage tanks as this will contaminate the machine
with bacteria. Prior to dumping the sanitizing
solution from the pail, submerse your hands to
sanitize since you must next install the Gravity Feed
Tube or Pump Feed Elbow into the cylinder feed
hole.
Press the “Stop – Reset” button (#571.1) and place the
machine in the OFF / Stop mode. Allow the sanitizer to
remain in contact with all of the product surfaces for
3 to 5 minutes.
Place the clean pail under the dispensing head and pull
the handles, allow the sanitizer to completely drain
from the freezer.
With your spatula, direct any remaining liquid in the
bottom of the tank to the cylinder feed hole.
571.1