12
Part III–Initial Cleaning Procedure
!! IMPORTANT !!
Before starting this procedure, place the machine in
the STOP mode on the touch pad.
This is a new machine and although clean, it must be
completely disassembled, washed and sanitized
before adding fresh product. Please proceed as
follows:
1) Remove the mix tank cover and spare parts items
packed inside the mix tank. The spare parts kit will
include: spatula, cleaning brushes, sanitary
lubricant, oring removal tool, sanitizer packets,
spare orings and seals, and operation manual. Place
these items in a convenient place for future
reference.
Helpful Suggestion:
Before proceeding with the
disassembly of the freezer, we recommend the use of
a clean plastic pan or pail to place the removed parts
into. This will minimize the possibility of misplacing
or damaging these components.
A) Gravity Fed Cleaning Procedure
Proceed with the disassembly process by removing
the gravity feed tube, which is located inside the mix
storage tank. The tube should be pulled straight up
and out of the tank.
Once removed, the gravity feed tube must be
disassembled. To disassemble, first remove the
splash guard from the center of the tube.
Next remove the outer regulating sleeve from the center
tube by pulling straight off.
Finally remove the orings on the end of the center tube
using
ONLY
the oring removal tool included in your
spare parts kit.
!! WARNING !!
Never use anything other than the oring remover
provided in your tool kit. Removing the orings with
other objects or tools can possibly damage the orings
and plastic parts.