B) Pump Fed Cleaning Procedure
Proceed with the disassembly of the mix injection
pump located in the mix storage tank. First slide the
connecting tube forward away from the mix pump
faceplate. This should free the feeding elbow assembly
from the pump assembly. Pull the feed elbow assembly
straight up and out of the mix storage tank.
Next remove the mix pump assembly by rotating
clockwise until the hook stud on the rear of the pump
disengages from the pump hub. After disengaging,
slide the pump away from the rear of the machine and
out of the mix storage tank.
Disassemble the mix pump assembly as pictured
below. When disassembling the orings from the other
components, use only the oring removal tool provided
in the spare parts tool kit. Using other tools to remove
the orings from their grooves can result in damaging
both the oring and component.