9
Chart of Indicators
MODEL 2302-B
Steady light:
Flashing light:
/
/
(Red / Yellow / Green)
/
/
(Red / Yellow / Green)
Explanation
Display of Indicators
Trigger
System Reaction
Corrective Action
Battery being charged
Battery fully charged
Electrical system is
turned on
Pilot Light is lit
Hot water
warning
(chamber)
Water temperature at heat
exchanger exceeds 131°F.
Gas will be cut off immediately. Pump will
be shut off in 30 seconds.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Hot water
warning
(water outlet)
Water temperature at water
outlet exceeds 122°F.
Gas will be cut off immediately. Pump will
be shut off in 30 seconds.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Tilt
warning
Heater is tilted more than 30
degrees.
Gas & pump will be shut off immediately.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Flames out
warning
Flames out / pilot light out
Gas & pump will be shut off immediately.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Low battery
warning
In-house battery voltage is
lower than 9.8V.
Gas & pump will be shut off immediately.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Low water flow
warning
Water flow rate is lower that
0.4 gallon (1.5 L)/min.
2 seconds after the first warning is
signaled, system will detect the flow rate
again; if the flow rate is still lower than the
specified level, gas & pump will be shut off.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
MODEL 2302-A
Explanation
Display of Indicators
Trigger
System Reaction
Corrective Action
Battery being charged
(animated)
Battery fully charged
Pilot Light is lit
Water is running
Hot water
warning
(chamber)
Water temperature at heat
exchanger exceeds 131°F.
Gas will be cut off immediately. Pump will be
shut off in 30 seconds.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Hot water
warning
(water outlet)
Water temperature at
water outlet exceeds
122°F.
Gas will be cut off immediately. Pump will be
shut off in 30 seconds.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Tilt
warning
Heater is tilted more than
30 degrees.
Gas & pump will be shut off immediately.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Flames out
warning
Flames out / pilot light out
Gas & pump will be shut off immediately.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Low battery
warning
In-house battery voltage is
lower than 9.8V.
Gas & pump will be shut off immediately.
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Low water flow
warning
Water flow rate is lower
that 0.4 gallon (1.5 L)/min.
Gas & pump will be shut off 2 seconds later
Turn off the control knob and the power button.
See troubleshooting section and solve the
problem, then restart the ignition sequence.
Summary of Contents for 2302-A
Page 40: ...39 NOTE REMARQUE NOTA ...