Programmable Input Lines
To connect I/O devices to one or more programmable input lines, first connect an I/O
extension cable (part number 300-0240), and optionally a DB-25 extension cable
(185-0334) and terminal block (195-0330), to the frame grabber’s P4 and/or P6
connector. Use Table 9 to determine the pins to use on the 300-0240 cable’s DB-25
connector or on the 195-0330 terminal block.
Opto-isolated inputs on P4 and P6 share the anode (+) pin between two lines. See
Programmable Line Input Circuitry
on page 73 for a wiring diagram for this connection
type.
Signal Name
P4 Pin (DB-25
and terminal
block)
P6 Pin (DB-25
and terminal
block)
Notes
OPTO
3
Not available with
I/O option 3
OPTO_IN_0–
4
OPTO_IN_1–
5
OPTO
11
OPTO_IN_2–
12
OPTO_IN_3–
13
OPTO
3
OPTO_IN_4–
4
OPTO_IN_5–
5
OPTO
11
OPTO_IN_6–
12
OPTO_IN_7–
13
Table 9.
DB-25 connection for opto-isolated input lines