2
MVS-8100D Hardware Description
Cognex MVS-8100D and CDC Cameras Hardware Manual
39
Wiring Methods
Figure 18 shows the methods for connecting input and output signal lines to the
respective terminal plugs of the external I/O module.
Figure 18. Wiring methods for connecting to the external I/O module
For both input and output signal lines, connect the source side of the signal to a
positive-numbered terminal and the sink side to a negative-numbered terminal.
Mechanical and Electrical Specifications
The following table lists the mechanical and electrical specifications for the external I/O
module:
Specification
Description
Dimensions
4.688 in (width) X 2.375 in (height) X 3.25 in (depth)
1.91 cm (width) X 6.03 cm (height) X 8.26 cm (depth)
Mounting
#3 DIN rail mountable
Operating Voltage
(Field Side)
5 V to 24 V DC
Table 20. External I/O module specifications
+5 to +24 VDC
+
–
Sin
k
Sourc
e
Sin
k
Sourc
e
Power supply
Input
Block
Output
Block