Cognex CDC Series Camera Description
Cognex MVS-8100D and CDC Cameras Hardware Manual
55
Installation of trigger and strobe devices is discussed in
Trigger Input Features
The trigger input is used to initiate the acquisition of an image from the camera. A pair
of connections, and Trigger–, provide optically isolated trigger inputs.
The schematic of the external trigger input circuit is shown in Figure 28.
Figure 28. Trigger input schematic
To activate a trigger, between 5 and 24 V peak-to-peak must be applied to the
terminals. Cognex software provides methods to enable triggers and to specify the
following trigger properties:
•
The polarity of the trigger pulse. That is, whether the image acquisition occurs on a
rising or falling pulse.
•
An acquisition delay period after acceptance of the trigger pulse. This feature
allows each image acquisition to be delayed by a specified number of
microseconds to take into account, for example, a light source’s warm-up period,
or the amount of time for an object to come into the camera’s view on a moving
assembly line.
The next two trigger properties allow for noise spikes to be filtered out and not treated
as trigger pulses.
•
The width of the trigger pulse. That is, the minimum duration of the pulse to be
considered a valid trigger.
•
The period of the trigger pulse. That is, how long to expect between trigger pulses
for a pulse to be considered valid.
Opto-isolator
+3.3 V
Trigger –
T
1.5K
Ω
1.5K
Ω
Camera
Trigger
Input