English
11
WARNING !!
Insert the lenses gently observing the points of reference. A wrong insertion can seriously damage the leds.
5. Powering up
5.1 Operating voltage and frequency
The unit may operates at voltages ranges from 90 to 250VaC at a frequency of 50 or 60 Hz. It is not needed to effect any setup
procedures, Stage Lite Led sc will automatically adjust its operation to suit any frequency or voltage within this range.
5.2 Connection to mains power
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent International standards.
Note: in case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3 X
1,5 ø external 10 mm, rated 300/500V, tested to 2 KV, operating temperature
-
40°C
+
180°C,
Coemar
cod. CV5311).
Connection to mains power
Stage Lite Led sc
is equipped with two power connectors, one as input and one as output, which can be used to connect more
fixtures in series.The maximum current absorbed from
Stage Lite Led sc
is indicated in the chart below:
-230/240V 0,5A amps constant current in normal operation.
-100/115V 1A amps constant current in normal operation.
The maximum working current of the connectors is 16A.
WARNING !
The absorbtion of Stage Lite Led sc (I max) can never be more than 16 A.
The maximum absorption Imax is given from the sum of the absorptions of all the
Stage Lite Led sc
connected in series.
Example:
For a series of 5
Stage Lite Led sc
connected at 100V
Imax = 1 X 5 = 5A
For a series of 5
Stage Lite Led sc
connected at 230V
Imax = 0,5 X 5 = 2,5A
In the following figure you can see an example of series connection: