background image

English 

 

 

Congratulations on having purchased a Coemar product. You have assured yourself of a fixture of the highest quality, both in the 

componentry and in the technology used. We renew our invitation to you to complete the service information form on the previous 

page. This will assist in providing prompt and accurate advice from your Coemar service centre, which you can thoroughly trust and 

to which you can submit any requests for service or information. Following the instructions and procedures outlined in this manual 

will ensure the maximum efficiency of this product for years to come. 

1.Packaging and transportation 

1.1 Packaging 

 

Open the packaging and make sure that no part of the equipment has suffered any damage during the transportation. In case of 

damage to the fixture, contact your currier and your supplier immediately by telephone, fax or email, and inform them you will  

formally notify them in writing through registered letter. 

Packing List 

Make sure the packaging contains: 
1 Stage Lite Led sc 

2 This instruction manual. 

3 Cam

-

Lock support brackets. 

4-Cam Lock brackets for floor support. 

 

1.2 Transportation 

Stage Lite Led sc must be transported exclusively in its original packaging or in an appropriate flight case.

 

2. General information 

2.1 Important safety information. 

Fire prevention: 

 

1.

Never locate the fixture on any flammable surface. 

2.

Minimum distance from flammable materials: 0,5m. 

3.

Minimum distance from the closet illuminable surface: 0,5m. 

4.

Replace any blown or damaged fuse only with those of identical values. Refer to the schematic diagram if there is any doubt. 

5.

 Connect the projector to mains power protected by a thermal magnetic circuit breaker.

 

Preventing from electric shock. 

1.

 Presence of high voltage inside of the fixture. Insulate the projector from mains supply before opening or performing any function 

which involves touching the inside of the fixture, including lamp replacement.. 

2.

 For the connection to the mains, adhere strictly to the guidelines outlined in this manual. 

3.

 The level of technology of 

Stage Lite Led sc

 requires the use of specialised personnel for all service applications; refer all work 

to your authorised 

Coemar 

service centre. 

4.

 A good earth connection is essential for the proper functioning of the projector. Never connect the fixture if there is no earth 

connection. 

5.

Mains cables must not come into contact with other cables. 

6.

Do not operate the projector with wet hands or in an area where water is present. 

7.

The fixture must never be located in an exposed position, or in areas of extreme humidity. 

Safety.

 

1.

 The projector must always be installed with bolts, clamps, or other fixing devices which are suitably rated to support the weight of 

the projector. 

2.

 Always use a secondary safety fixing device with chain or steel wire of a suitable rating to sustain the weight of the unit in case of  

failure of the principal fixing point. 

3.

 The external surfaces of the unit, at various points, may reach 80°C. Never handle the unit until at least 10 minutes have elapsed 

since the lamp was turned off 

4.

 Never install the fixture in an enclosed area lacking sufficient air flow; the room temperature must not exceed 35°C. 

5. 

The projector contains electronic and electrical components which must under no circumstances be in contact with water, oil or 

any other liquid. Failure to do so will compromise the proper functioning of the projector. 

 

Protection rating against penetration by external agents (versione IP65): 

The fixture has an IP65 protection rating; this indicates that it is protected against dust and significant showers of water. This 

protection rating allows the fixture to be installed in an exposed location in inclement weather conditions.. 

2.2 Warranty conditions 

1. The fixture is guaranteed for a period of 12 months from the date of purchase against manufacturing or materials defects. 
2. The warranty does not extend to damage caused by inappropriate usage, use by inexperienced operators or inadequate 

maintenance. 

3. The warranty is immediately void if the projector has been tampered or opened by unauthorised personnel. 

4. The warranty does not extend to fixture replacement.

 

5. Both the serial number and the model  of the projector are required for any advice or service from your authorised service centre.

 

2.3 EC norms.

 

The projector meets all fundamental applicable EC requirements. 

Summary of Contents for Stage Lite Led sc

Page 1: ...Stage Lite Led sc instruction manual manuale di istruzioni Version 1 0 DIS131 ...

Page 2: ... in answering any tecnica enquiries with the utmost speed and accuracy Prendete nota nello spazio apposite dei dati relative al modello e al rivenditore del vostro Stage Lite Led sc questi dati ci permetteranno di assistervi con la massima rapidità e precisione WARNING the security of the fixture is granted only if these instructions are strictly follone therefore it is absolutely necessary to kee...

Page 3: ...1 5 1 Operating voltage and frequency 11 5 2 Connection to mains power 11 6 Control signal connections 12 6 1 Control signal connection by XLR3 plugs 13 7 Turning on the projector 13 7 1 DMX address of the unit 13 7 2 DMX functions 14 8 Display panel functions 15 8 1 Quick guide to menu 15 8 2 Rapid count 15 8 3 MODE menu 15 8 4 Test and measures MEAS 16 8 5 Function settings FUNC 16 8 6 Connectin...

Page 4: ...e use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essential for the proper functioning of the projector Never connect the fixture if there is no earth connection 5 Mains cables must not come into contact with other cables 6 Do not operate the projector with wet hands or in an area where water is present ...

Page 5: ...Weight 6 Kg 13 2 lbs IP rating IP20 standard version IP65 IP version The technological heart of Stage Lite Led sc is made of 48 powerful leds projecting infinite combinations of colors mounted on three parallel 180 manually orientating bars In the following pages for convention these bars are called lines and are enumerated from the bottom line 1 line 2 and line 3 3 2 Dimensions Suspended installa...

Page 6: ...s Components description 1 Top frame 7 Adjusting knobs 2 Polycarbonate screen 8 Unit housing 3 Internal led lines group 9 Left header 4 Right header 10 DMX IP20 panel 5 Led controller PCB 11 Display panel 6 Power supply unit 12 Gasket 1 2 3 4 5 6 7 8 9 10 11 12 12 ...

Page 7: ...e following diagram WARNING Always ensure that your support structure and fixing bolts clamps etc are rated to support the weight of the fixture Floor installation If the fixture is floor mounted we recommend the use of appropriate clamps C as shown in the following diagram 4 2 Safety chain When hanging Stage Lite Led sc we recommend the use of a safety chain affine to the body and to the suspensi...

Page 8: ... The instruction for replacing the lenses are showed in the following pictures This operation must be done by qualified personnel remove the frame or the IP65 panel from the bottom of the fixture by unscrewing the 4 screws then remove also the other 2 screws placed underneath in order to unlock the inner block remove the three adjusting knobs and the right side header from the fixture by removing ...

Page 9: ...ternal 10 mm rated 300 500V tested to 2 KV operating temperature 40 C 180 C Coemar cod CV5311 Connection to mains power Stage Lite Led sc is equipped with two power connectors one as input and one as output which can be used to connect more fixtures in series The maximum current absorbed from Stage Lite Led sc is indicated in the chart below 230 240V 0 5A amps constant current in normal operation ...

Page 10: ...l connections Stage Lite Led sc can operate in two modes 1 using DMX512 control signal 2 automatic STAND ALONE or MASTER SLAVE mode 6 1 Control signal connection by XLR3 plugs The digital control signal is transmitted to the projector via a two pole cable screened as per International standards for the transmission of DMX 512 data The connection must be serial using connectors XL3 male and female ...

Page 11: ...each projector will show A001 which indicates DMX address 001 a projector thus addressed will respond to commands of channel 1 to 8 from your DMX 512 controller A second unit must be addressed as A016 a third as A024 and so on The operation must be carried out on every Stage Lite Led sc which has an address different from A001 Altering DMX address 1 Press the or button until the display shows the ...

Page 12: ...English 14 7 2 DMX functions ...

Page 13: ... time the key or will be pressed To select the desired function press enter 8 2 Rapid count By the display panel of Stage Lite Led sc It is possible to quickly change the various numbers displayed for the different functions in the following 3 manners 1 Pressing the or buttons will cause the count to be quicker 2 Pressing first and then and then holding them down simultaneously will cause the numb...

Page 14: ...larm Eg version code Eg value Eg value Life of the leds Life of the unit To set all the functions at the default values Test functions Test red Test green reverse Test white Test strobo To record the scene of the unit If DMX signal is not applied the recorder setting will appear at the end of reset operation when the unit is switched on Enter to confirm Enter to confirm Test blue It disables butto...

Page 15: ...e units This may jeopardize the functioning of the entire system DR1 and DR1 Plus will show an error message For further information consult the DR1 or DR1 Plus manual 8 7 Electronic led alignment The display of Stage Lite Led sc enables the alignment of the leds this procedure has been done by Coemar before leaving the factory It may be needed to modify these settings in case of internal parts re...

Page 16: ...the error persists it means that the EEprom is either defective or absent refer to your Coemar service center for the replacement DMX address error The projector is not receiving all the DMX channels necessary for its operation Check the DMX address and the control consolle operation Note that some controllers may not generate all 512 channels of signal Master mode error This message indicates tha...

Page 17: ...aner or a source of compressed air for removing dust from the heat sink on the back of the unit For the cleaning of the housing use a soft cloth and a non aggressive cleaner 11 2 Periodic controls Mechanical parts Check the correct working of the mechanical parts and if needed replace them Make sure the projector is not mechanically damaged If necessary replace the worn parts Electrical components...

Page 18: ...the DMX chain 2 Stage Lite Led sc receives a DMX signal 3 There wasn t set any program 1 Locate the other unit set as MASTER and set it as SLAVE 2 Remove eventual DMX connection 3 Set a program on MASTER unit Stage Lite Led sc is not recognized by DR1 or DR1 Plus ID set as 0 or another unit with the same ID is in the DMX chain Change the setting of the ID number different from 0 and different from...

Page 19: ...2 A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modifications without notification ...

Reviews: