English
18
8.4 Tests and measures (Measures)
The internal microprocessor of Reflection allows for several diagnostic and output paramenter to be displayed.
MEASURES
It shows temperature measured by the sensors in the unit:
Tboard, Tled, Tdriver, Tsens.
It shows the values in Volt of the mains power, the fans and pump: V
alim
,
V
rad, Vfan, Vpump.
It shows the DMX value(0-255) received on each DMX channel used by
the unit on the DMX chain.
Reading of the typical DMX value called RATE ( frequency of signal
updating in milliseconds).
It shows the error message of the alarm in progress.
It shows the luminous efficiency of the RGBW
leds.
It shows the led’s life values in hours:
led life (r):
led module life
(resettable);
led life:
life of total modules installed on the unit since now
(not resettable);
unit life:
life of the projector.
It shows the led’s emission frequency. It may be useful if frequency must
be set due to flicker issues.
TEMPERATURE
VOLTAGE
DMX INPUT MEASURE
DMX RATE
ALARM STATUS
LED STATUS
USAGE HOURS
LED FREQUENCY
RED: 80%
GREEN: 30%
BLUE: 10%
WHITE: 100%
It shows the actual software version installed on the unit :
sw master
Reflection.
.
SOFTWARE VERSION
Summary of Contents for Reflection FullSpectrum